Roadway Pole Spacing

Estimate same-side pole pitch, setback geometry, and connected power for roadway or parking-lot lighting layouts.

Road and mounting
ft
ft
ft
×
Luminaire and target
lm
fc
W
Pole pitch
262.5ft
Pitch / height
8.75×
Pole density
40.2poles/mi
Linear power
2.32kW/km

Pole elevation and layout plan

Edit inputs ↓
Pole elevation and layout planCURB SECTIONROADWAY PLANH 30 ftStaggeredArm 4 ftS 262.5 ftMaintained target0.85 fc
Pitch is measured along one side. A staggered arrangement offsets the opposite row by half the pitch.

RP-8 layout screen

Review needed
OutsideThresholdWithin
  • Same-side pitch / height8.75 / ≤ 4 × outside screen

Comparison uses the entered pitch criterion. Use the relevant RP-8 limits in a point-by-point pavement grid.

Additional readings
Luminaires per repeat2
Combined light loss factor0.765
Maintained delivered flux per repeat8,032.5lm
Area-normalized connected power0.02W/ft²
Optical overhang4ft
Distance to next pole station131.25ft
Pitch limit from height criterion120ft

Calculation method

Select a maintained illuminance target for the road or parking class. Apply the street-side utilization and light loss to the flux in one repeating roadway cell.

Maintained lumens through one cell
Φcell = Φ × CU × LLD × LDD × fixtures per repeat
Same-side pole pitch
S = Φcell/(Eavg × roadway width)
Pole density and power
Poles/km = 1000 × fixtures per repeat/S · kW/km = poles/km × W/1000

The supplied spacing / height limit is a project heuristic. Verify RP-8 pavement uniformity, glare, luminance, and classification using grid photometry.

Sources and assumptions ↗