Roadway Pole Spacing
Estimate same-side pole pitch, setback geometry, and connected power for roadway or parking-lot lighting layouts.
Inputs
View results ↑- Pole pitch
- 262.5ft
- Pitch / height
- 8.75×
- Pole density
- 40.2poles/mi
- Linear power
- 2.32kW/km
Pole elevation and layout plan
Edit inputs ↓RP-8 layout screen
Review needed- Same-side pitch / height8.75 / ≤ 4 × outside screen
Comparison uses the entered pitch criterion. Use the relevant RP-8 limits in a point-by-point pavement grid.
Additional readings
| Luminaires per repeat | 2 |
|---|---|
| Combined light loss factor | 0.765 |
| Maintained delivered flux per repeat | 8,032.5lm |
| Area-normalized connected power | 0.02W/ft² |
| Optical overhang | 4ft |
| Distance to next pole station | 131.25ft |
| Pitch limit from height criterion | 120ft |
Calculation method
Select a maintained illuminance target for the road or parking class. Apply the street-side utilization and light loss to the flux in one repeating roadway cell.
- Maintained lumens through one cell
- Φcell = Φ × CU × LLD × LDD × fixtures per repeat
- Same-side pole pitch
- S = Φcell/(Eavg × roadway width)
- Pole density and power
- Poles/km = 1000 × fixtures per repeat/S · kW/km = poles/km × W/1000
The supplied spacing / height limit is a project heuristic. Verify RP-8 pavement uniformity, glare, luminance, and classification using grid photometry.
Sources and assumptions ↗Roadway Pole Spacing
Inputs
| Pole configuration | Staggered |
|---|---|
| Roadway width | 36ft |
| Mounting height | 30ft |
| Optical overhang past curb | 4ft |
| Max pitch / mounting height | 4× |
| Output per pole | 12,500lm |
| Street-side utilization | 0.42 |
| Lumen depreciation (LLD) | 0.9 |
| Dirt depreciation (LDD) | 0.85 |
| Maintained roadway target | 0.85fc |
| Input per pole | 93W |
Results
| Pole pitch | 262.5ft |
|---|---|
| Pitch / height | 8.75× |
| Pole density | 40.2poles/mi |
| Linear power | 2.32kW/km |
| Luminaires per repeat | 2 |
| Combined light loss factor | 0.765 |
| Maintained delivered flux per repeat | 8,032.5lm |
| Area-normalized connected power | 0.02W/ft² |
| Optical overhang | 4ft |
| Distance to next pole station | 131.25ft |
| Pitch limit from height criterion | 120ft |
RP-8 layout screen
- Same-side pitch / height · 8.75 / ≤ 4 × · Outside screen
Comparison uses the entered pitch criterion. Use the relevant RP-8 limits in a point-by-point pavement grid.
The supplied spacing / height limit is a project heuristic. Verify RP-8 pavement uniformity, glare, luminance, and classification using grid photometry.