High-cone snap-through screen

A thin conical washer is loaded well past mid-stroke in a displacement-controlled fixture.

Input units
Stack load 1,680.6 N
Disc load 1,680.6 N
Disc flat load 1,614.6 N
Peak edge 4,723.3 MPa

Anatomy

Stack section and Almen–László curve

Edit inputs
Stack section and Almen–László curveSchematic view with the current loads and dimensions. DISC STACKSTACK FORCENested × opposedTravel to flatStack travel1.55 mmStack force1,681 NStack flat load1,615 N

Screening margins

Exceeds screen
  • Edge stress4,723 MPa / 1,450 MPa
    Exceeds screen
  • Travel to flat1.55 mm / 1.65 mm
    Near limit
  • Snap-through threshold129.6% of limit
    Exceeds screen

Calculated values

Stack load at entered travel1,680.6 N
Single-disc load1,680.6 N
Single-disc flat load1,614.6 N
Peak absolute edge stress4,723.3 MPa
Diameter ratio Rᵈ1.9325
Cone ratio h₀/t1.8333
Load coefficient M / K₁0.67986
Edge coefficient C₁ / K₂1.2043
Edge coefficient C₂ / K₃1.3516
Travel per series group1.55 mm
Travel to flat stack1.65 mm
Stack load at flat1,614.6 N
Stack tangent stiffness-647.82 N/mm
I · Upper inner edge-4,723.3 MPa
II · Lower inner edge338.55 MPa
III · Lower outer edge2,721.7 MPa
IV · Upper outer edge102.43 MPa

Starting result

The tangent slope can turn negative before flat when the cone height exceeds √2 times thickness.

Cone ratio h₀/t
1.8333
Stack tangent stiffness
-647.82 N/mm
I · Upper inner edge
-4,723.3 MPa

Model and assumptions

F = [4Et⁴/((1−ν²)M·OD²)] · (s/t)[(h₀/t−s/t)(h₀/t−s/(2t))+1]

Uniform thickness, sharp rectangular section, no contact flats, no stack friction. Series groups share travel and nested discs share force. The warning at h₀/t > √2 flags a negative-slope region before flat.

References and calculation method

Worked examples

Open the standard calculator