Parallel Shaft Key and Keyway Calculator
Compare key shear and keyway bearing stress, then find the effective engagement length for a target safety factor.
Anatomy
Shaft cross-section and loaded key flank
Screening margins
Within screen-
Key shear82.03 MPa / 213.6 MPa
Within screen -
Flank bearing205.1 MPa / 280 MPa
Within screen
Calculated values
| Average key shear stress | 41.016 MPa |
|---|---|
| Average side bearing stress | 102.54 MPa |
| Governing yield safety factor | 2.7307 × |
| Minimum effective engagement | 23.438 mm |
| Applied key width | 10 mm |
| Applied key height | 8 mm |
| Transferred tangential force | 13,125 N |
| Transmitted torque | 210 N·m |
| Distortion-energy shear yield | 213.62 MPa |
| Lower bearing yield limit | 280 MPa |
| Length for shear target | 12.288 mm |
| Length for bearing target | 23.438 mm |
Model and assumptions
τ = 2T/(dwL) · σb = 4T/(dhL) · Lmin = max(Lshear, Lbearing) at the chosen factor
One parallel key with half-height bearing and uniform load along the effective length. Exclude rounded ends from engagement. Presets give nominal sections. The shaft’s notch fatigue and hub wall stress need their own evaluation.
References and calculation method