Calculators Joints

Preloaded Bolted Joint Calculator

Compare retained clamp, proof load, separation and Goodman fatigue on an axially loaded single-bolt joint.

Input units
Load fraction 0.19155
Bolt tension 44,310 N
Clamp force 21,810 N
Separation 49,477 N

Anatomy

Bolt extension and clamp release

Edit inputs
Bolt extension and clamp releaseSchematic view with the current loads and dimensions. JOINT SECTIONJOINT FORCEExternal pull PAxial displacementPreload Fᵢ40,000 NBolt Fᵦ44,310 NClamp Fₘ21,810 N

Screening margins

Within screen
  • Separation22,500 N / 49,480 N
    Within screen
  • Bolt proof load44,310 N / 69,970 N
    Within screen
  • Goodman fatigue62.56% of limit
    Within screen

Calculated values

Bolt load fraction C0.19155
Peak bolt tension Fᵦ44,310 N
Remaining clamp Fₘ21,810 N
External separation load Pₛₑₚ49,477 N
Tensile stress area Aₜ84.3 mm²
Bolt proof strength Sₚ830 MPa
Axial bolt stiffness kᵦ633,930 N/mm
Axial member stiffness kₘ2.6755e6 N/mm
Linear clamp reserve21,810 N
Bolt proof load69,969 N
Separation factor n₀2.199 ×
Proof factor nₚ1.5791 ×
Cycle mean tensile stress502.9 MPa
Alternating tensile stress22.722 MPa
Nominal Goodman factor1.5985 ×

Model and assumptions

C = kᵦ/(kᵦ+kₘ) · Fᵦ = Fᵢ+CP · Fₘ = Fᵢ−(1−C)P before separation

Centered axial tension with unit load introduction. The estimate uses bolt thread and shank compliance and two symmetric 30° member frusta. After separation the bolt carries the full load and retained clamp is zero.

References and calculation method

Worked examples