Two convex cylinders
Two cylinders of different radii contact along a common line under a distributed normal load.
Anatomy
Contact footprint and subsurface shear
Screening margins
Within screen-
Subsurface shear290.9 MPa / 400 MPa
Within screen -
Peak contact pressure968.7 MPa / 1,500 MPa
Within screen -
Small contact patch0.1361 mm / 1.2 mm
Within screen
Calculated values
| Peak Hertz pressure p₀ | 968.67 MPa |
|---|---|
| Line half-width b / point radius a | 0.13614 mm |
| Peak subsurface shear | 290.87 MPa |
| Depth of peak shear | 0.10702 mm |
| Reduced elastic modulus E* | 115,380 MPa |
| Equivalent radius R* | 8.1081 mm |
| Projected contact footprint | 3.8118 mm² |
| Peak shear / peak pressure | 0.30028 |
| Depth / contact half-width | 0.78615 |
Starting result
The equivalent radius is smaller than either convex radius, tightening the contact footprint.
- Equivalent radius R*
- 8.1081 mm
- Projected contact footprint
- 3.8118 mm²
- Peak subsurface shear
- 290.87 MPa
Model and assumptions
E* = 1/Σ[(1−ν²)/E] · R* = 1/Σ(1/R) · b² = 4FR*/(πLE*) · a³ = 3FR*/(4E*)
Smooth, elastic, frictionless bodies with a small contact patch. Line shear is the in-plane 45° shear below the centerline. Circular contact uses the larger centerline shear from the two Poisson ratios.
References and calculation method