Shrink-fit heating allowance
A shop adds 0.04 mm of handling clearance above the diametral interference before assembly.
Anatomy
Interface section and Lamé stress field
Screening margins
Within screen-
Hub bore yielding174.8 MPa / 350 MPa
Within screen
Calculated values
| Interface pressure p | 68.005 MPa |
|---|---|
| Peak hub hoop stress | 130.54 MPa |
| Axial press force at full length | 98,703 N |
| Static slip torque capacity | 2,714.3 N·m |
| Hub radial stress at bore | -68.005 MPa |
| Hub hoop stress at OD | 62.536 MPa |
| Hub bore von Mises stress | 174.77 MPa |
| Hub yield factor | 2.0027 × |
| Hub heating ΔT above shaft | 141.76 °C |
Starting result
The reported ΔT is a temperature rise relative to the shaft. Larger assembly clearance requires more heating.
- Hub heating ΔT above shaft
- 141.76 °C
- Interface pressure p
- 68.005 MPa
- Static slip torque capacity
- 2,714.3 N·m
Model and assumptions
p = (δ/d)/[(H+νh)/Eh+(S−νs)/Es] · F = πdLμp · T = Fd/2
Long concentric members with open ends and uniform pressure. Yield is checked at the hub bore under plane stress. Assembly heating assumes a shaft held at its initial temperature and a constant hub expansion coefficient.
References and calculation method