Key load from power and speed
A drive transmits 8 kW at 720 rpm through a standard metric key.
Anatomy
Shaft cross-section and loaded key flank
Screening margins
Within screen-
Key shear52.01 MPa / 213.6 MPa
Within screen -
Flank bearing118.9 MPa / 280 MPa
Within screen
Calculated values
| Average key shear stress | 26.006 MPa |
|---|---|
| Average side bearing stress | 59.442 MPa |
| Governing yield safety factor | 4.7105 × |
| Minimum effective engagement | 14.436 mm |
| Applied key width | 8 mm |
| Applied key height | 7 mm |
| Transferred tangential force | 7,073.6 N |
| Transmitted torque | 106.1 N·m |
| Distortion-energy shear yield | 213.62 MPa |
| Lower bearing yield limit | 280 MPa |
| Length for shear target | 8.2782 mm |
| Length for bearing target | 14.436 mm |
Starting result
Power and shaft speed determine torque before the key shear and bearing checks.
- Transmitted torque
- 106.1 N·m
- Transferred tangential force
- 7,073.6 N
- Minimum effective engagement
- 14.436 mm
Model and assumptions
τ = 2T/(dwL) · σb = 4T/(dhL) · Lmin = max(Lshear, Lbearing) at the chosen factor
One parallel key with half-height bearing and uniform load along the effective length. Exclude rounded ends from engagement. Presets give nominal sections. The shaft’s notch fatigue and hub wall stress need their own evaluation.
References and calculation method