Key load from power and speed

A drive transmits 8 kW at 720 rpm through a standard metric key.

Input units
Key shear 26.006 MPa
Flank bearing 59.442 MPa
Safety factor 4.7105 ×
Min. length 14.436 mm

Anatomy

Shaft cross-section and loaded key flank

Edit inputs
Shaft cross-section and loaded key flankSchematic view with the current loads and dimensions. SHAFT SECTIONKEY ENGAGEMENTOrange = loaded flankEffective bearing lengthForce Fₜ7,074 NKey shear τ26.01 MPaFlank bearing59.44 MPa

Screening margins

Within screen
  • Key shear52.01 MPa / 213.6 MPa
    Within screen
  • Flank bearing118.9 MPa / 280 MPa
    Within screen

Calculated values

Average key shear stress26.006 MPa
Average side bearing stress59.442 MPa
Governing yield safety factor4.7105 ×
Minimum effective engagement14.436 mm
Applied key width8 mm
Applied key height7 mm
Transferred tangential force7,073.6 N
Transmitted torque106.1 N·m
Distortion-energy shear yield213.62 MPa
Lower bearing yield limit280 MPa
Length for shear target8.2782 mm
Length for bearing target14.436 mm

Starting result

Power and shaft speed determine torque before the key shear and bearing checks.

Transmitted torque
106.1 N·m
Transferred tangential force
7,073.6 N
Minimum effective engagement
14.436 mm

Model and assumptions

τ = 2T/(dwL) · σb = 4T/(dhL) · Lmin = max(Lshear, Lbearing) at the chosen factor

One parallel key with half-height bearing and uniform load along the effective length. Exclude rounded ends from engagement. Presets give nominal sections. The shaft’s notch fatigue and hub wall stress need their own evaluation.

References and calculation method

Worked examples

Open the standard calculator