MotionMechLab

TR8×8 vs SFU1605 driving torque at equal thrust

Compare common 8 mm lead trapezoidal and 5 mm lead ball screws at a shared 500 N axial load.

Jump to results ↓

Inputs

Screw geometry
mm
Enter 0 for a profile estimate. A custom screw needs a root diameter.
%
Enter 0 for the profile assumption.
mm
Load & operating limits
N
rpm
N·m
×
rpm
Enter 0 if the nut or assembly limit is unknown.

Results

Preset estimate
Driving torque
1.8189N·m
Driving torque contributions and axial load relative to the buckling screenSHAFT TORQUE1.819 N·mIdeal · losses · dragCOMPRESSION LOAD500 NBuckling screen 699.1 N
Uses an estimated root diameter. Replace it with the measured or catalog root diameter before choosing a shaft.
Driving torque (imperial)
257.58 oz·in
Screw lead
8 mm/rev
Thread pitch
2 mm
Thread starts
4
Root diameter
6.2 mm
Assumed efficiency
35 %
Ideal load torque
0.6366 N·m
Friction loss torque
1.1823 N·m
Extra nut / bearing drag
0 N·m
Shaft power
38.1 W
Linear feed
1,600 mm/min
Euler critical load
1,398.2 N
Screened compression limit
699.1 N
First critical speed
7,201 rpm
Whip speed screen (80%)
5,761 rpm
Practical speed limit
5,761 rpm

Worked example

The 8 mm lead TR8×8 needs about 1.82 N·m at 500 N and an assumed 35% efficiency. A 5 mm lead SFU1605 at 90% needs about 0.44 N·m at the same load before separate drag.

The comparison changes both lead and efficiency. To compare at equal feed, use 320 rpm on the SFU1605 for the 1,600 mm/min obtained at 200 rpm on TR8×8. Use your nut’s actual preload and friction data.

Driving torque 1.8189 N·m

Formulas

  • Lead = thread pitch × starts
  • Driving torque = thrust × lead / (2π η) + extra drag
  • Root-section moment I = π d⁴ / 64
  • Critical compressive load = π² E I / (K L)²
  • First critical RPM = 60 β² √(E I / (ρ A L⁴)) / (2π)
  • Screened compression limit = critical load / safety factor

References

Frequently asked questions

Why can a trapezoidal screw draw more torque at the same thrust?

Sliding contact can lose more energy to friction than rolling contact. A longer lead also raises ideal torque at the same force.

Does a low-efficiency TR8×8 always hold a load with the motor off?

Check the nut and screw for back-driving under actual loads. Efficiency alone is insufficient to assume a vertical load will hold.