Handle high volt-seconds in 48 V to 12 V 60 W buck converters
Dropping 48 V (up to 58.4 V on a charged 16S LiFePO4 pack) to 12 V at 5 A places 36–46 V across the inductor during switch conduction. Running at a moderate 200 kHz limits MOSFET switching losses while keeping the inductor around 33 µH.
Always check worst-case ripple at 58.4 V full charge voltage using the alternate preset so the inductor core never saturates at top of charge.
Formulas
D = 12 ÷ 48 = 25.0%L = 12 × 36 ÷ (48 × 200,000 × 1.50) = 30.0 µH → std 33 µHI_peak = 5.0 + 0.75 = 5.75 A; I_sat ≥ 7.48 A
Worked example
At 48 V in, 12 V / 5 A out and 200 kHz, minimum inductance is exactly 30.0 µH (standard 33 µH), peak current is 5.75 A, and a 20 mΩ inductor dissipates 0.504 W.