Size 2 oz heavy-copper traces for 10 A DC power buses
Doubling copper thickness from 1 oz (35 µm) to 2 oz (70 µm) immediately halves required trace width for the same cross-sectional area and milliohm resistance. For 10 A DC buses on motor controllers, power supplies and battery distribution boards, 2 oz copper keeps layouts manufacturable without massive busbars.
Always verify both thermal rise and DC voltage drop on 10 A traces: a seemingly small 15 mΩ trace still drops 150 mV and radiates 1.5 W of heat into adjacent components.
Formulas
Thickness_2oz = 2.756 mil (70 µm)Width_mil = Area_IPC2152 ÷ 2.756Heat dissipation = 100 A² × R_trace
Worked example
A 10 A trace on 2 oz external copper with a 20 °C rise and solid plane coupling requires ~74.8 mil (1.90 mm). Over 60 mm at 50 °C copper temp, resistance is ~8.7 mΩ, dropping 87 mV and losing 0.87 W.