Route a 5 A power trace on standard 1 oz FR-4 copper
Five amps is right near the crossover point where 1 oz copper traces start occupying noticeable board width. Under IPC-2152 with a 10 °C temperature rise and 2-layer plane coupling, a 5 A external trace typically requires over 100 mil (2.5+ mm) of copper width.
If routing channels are tight around connectors or switching regulators, allowing a 20 °C rise on a 4-layer board with a solid ground plane roughly halves the required width while keeping copper well below FR-4 Tg limits.
Formulas
Width_mil = Area_sqmil ÷ 1.378 mil (for 1 oz copper)Voltage drop = 5 A × R_trace(T_op)Power loss = 25 A² × R_trace(T_op)
Worked example
At 5 A and 10 °C rise on 1 oz external copper (standard 0.82× plane factor), IPC-2152 calculates ~108.5 mil (2.76 mm). Over 40 mm, trace resistance is ~7.5 mΩ, dropping 37.7 mV and dissipating 188 mW.