1 oz Copper PCB Trace Width for 5A Calculator (IPC-2152)

Size a 1 oz external PCB trace for 5 A continuous current using IPC-2152 thermal plane coupling, with milliohm resistance, voltage drop and CSV export.

Jump to results

Inputs

Current & thermal budget
Common baseline is 10 °C; power boards often allow 20–30 °C.
Board stackup & trace drop
Applies in IPC-2152 mode to account for copper plane heat spreading.

Results

Estimates
Minimum PCB trace width107.3 mil (2.73 mm)
Trace resistance
7.65 mΩ
Voltage drop
38.3 mV (0.32%)
Copper power loss
191.3 mW
Cross-sectional area
0.0954 mm² (147.9 mil²)
Operating copper temp
35 °C (52.4 A/mm²)
Internal equivalent
170.7 mil (4.34 mm)
PCB copper cross-section & weight comparison
W = 107.3 mil (2.73 mm)FR-4 Core (External Layer)t = 35 µm (1 oz)Reference Ground Plane (IPC2152) 0.5 oz (external) 214.7 mil · 5.45 mm 1 oz (external) 107.3 mil · 2.73 mm 2 oz (external) 53.7 mil · 1.36 mm 3 oz (external) 35.8 mil · 0.91 mm
Copper weight & layer comparison
CopperLayerWidth (mil)Width (mm)R (mΩ)Drop (mV)Loss (mW)
0.5 ozexternal214.75.457.6538.3191.3
0.5 ozinternal341.48.674.8124.1120.3
1 ozexternal107.32.737.6538.3191.3
1 ozinternal170.74.344.8124.1120.3
2 ozexternal53.71.367.6538.3191.3
2 ozinternal85.42.174.8124.1120.3
3 ozexternal35.80.917.6538.3191.3
3 ozinternal56.91.454.8124.1120.3

Calculated using IPC2152 at 35 °C copper temperature. Add copper pour or thermal vias if board airflow is restricted.

Route a 5 A power trace on standard 1 oz FR-4 copper

Five amps is right near the crossover point where 1 oz copper traces start occupying noticeable board width. Under IPC-2152 with a 10 °C temperature rise and 2-layer plane coupling, a 5 A external trace typically requires over 100 mil (2.5+ mm) of copper width.

If routing channels are tight around connectors or switching regulators, allowing a 20 °C rise on a 4-layer board with a solid ground plane roughly halves the required width while keeping copper well below FR-4 Tg limits.

Formulas

  • Width_mil = Area_sqmil ÷ 1.378 mil (for 1 oz copper)
  • Voltage drop = 5 A × R_trace(T_op)
  • Power loss = 25 A² × R_trace(T_op)

Worked example

At 5 A and 10 °C rise on 1 oz external copper (standard 0.82× plane factor), IPC-2152 calculates ~108.5 mil (2.76 mm). Over 40 mm, trace resistance is ~7.5 mΩ, dropping 37.7 mV and dissipating 188 mW.

Frequently asked questions

How wide should a 1 oz PCB trace be for 5 amps?

At 10 °C temperature rise on an external 1 oz layer, expect roughly 108–132 mil (2.7–3.4 mm) depending on ground-plane coupling, or ~60–75 mil if you allow a 20 °C rise.

Can I split 5 A across top and bottom 1 oz layers?

Yes. Parallel copper pours stitched with multiple thermal/current vias share current and double the effective cross-sectional area while keeping trace width compact.

Does solder mask opening with tinning reliably double 5 A trace capacity?

Solder has roughly 8× higher resistivity than copper, so solder-tinning adds unpredictable and modest current gain compared to widening copper or stepping up to 2 oz.