100kHz Synchronous Buck High-Side MOSFET Thermal Margin Calculator

Evaluate high-frequency switching loss vs. low-duty conduction loss for a 100 kHz buck converter high-side MOSFET.

Jump to results

Inputs

MOSFET electrical losses
Use RMS over the conduction interval. The switching estimate uses this value as a proxy for transition current.
Silicon MOSFET R_DS(on) typically rises 1.3×–1.6× at 100–125 °C.
Use 100% for a continuously ON load switch.
Set 0 kHz for pure DC static load switching.
Thermal stackup (J → C → S → A)
Silicone pad ~0.5–1.0 °C/W; bare grease ~0.2 °C/W.
No heatsink TO-220 free air is ~60 °C/W.

Results

Estimates
Estimated junction temp (TJ)61.5 °C (+88.5 °C margin)
Total MOSFET loss
1.19 W (0.42 W cond + 0.77 W sw)
Thermal status
Safe (≥ 25 °C margin)
Case / heatsink temp
TC = 59.9 °C · TS = 59.3 °C
Total R_θJA stackup
13.9 °C/W
Hot R_DS(on) used
16.8 mΩ
Max R_θSA for 25 °C margin
65.44 °C/W
Thermal resistance ladder & junction temperature gauge
RθJC 1.4 °C/W RθCS 0.5 °C/W RθSA 12 °C/W 62° Junction (TJ) 60° Case (TC) 59° Heatsink (TS) 45° Ambient (TA)TJ = 61.5 °C · Total loss = 1.19 WTJ,max = 150 °C
Heatsink thermal resistance comparison
Cooling optionR_θSA (°C/W)Est. TJ (°C)Margin to TJ,max25 °C Screen
Sink to ambient · 1.5 °C/W1.549101 °CPass
Sink to ambient · 3 °C/W350.899.2 °CPass
Sink to ambient · 6 °C/W654.495.6 °CPass
Sink to ambient · 12 °C/W1261.588.5 °CPass
Sink to ambient · 25 °C/W257773 °CPass
Sink to ambient · 62 °C/W62120.929.1 °CPass

Always verify SOA curves, gate-drive rise/fall times under real capacitive load, and airflow orientation against the heatsink datasheet.

Why switching loss dominates the high-side buck MOSFET

In a high step-down buck converter (such as 48 V to 12 V at 25% duty cycle), the high-side control MOSFET conducts for only a quarter of the cycle—keeping I²R conduction loss modest—while absorbing hard-switched 48 V turn-on and turn-off transitions on every single clock edge.

Use this preset to verify whether a lower gate-charge (faster tr/tf) MOSFET with slightly higher R_DS(on) runs cooler than a giant low-R_DS(on) device.

Formulas

  • P_cond = 10² × (0.012 × 1.4) × 0.25 = 0.42 W
  • P_sw = 0.5 × 48 × 10 × 32 ns × 100 kHz = 0.77 W
  • Total loss = 1.19 W (65% from switching!)

Worked example

At 100 kHz, 48 V and 10 A with 32 ns total switching time, switching loss (0.77 W) is nearly double conduction loss (0.42 W), yielding T_J = 61.5 °C on a compact 12 °C/W sink.

Frequently asked questions

Why should high-side and low-side buck MOSFETs often be different part numbers?

The high-side MOSFET needs low gate charge (Q_gd) to cut switching loss at low duty cycle, while the low-side synchronous MOSFET needs ultra-low R_DS(on) because it conducts 75% of the cycle with near-zero switching voltage.

What happens to high-side loss if I double f_sw from 100 kHz to 200 kHz?

Switching loss doubles directly from 0.77 W to 1.54 W while conduction loss stays flat—load the 200 kHz preset to see the exact T_J jump.

Does reverse recovery of the low-side body diode add heat to the high-side MOSFET?

Yes. Low-side Q_rr shoots through the high-side switch at turn-on, so choose a low-Q_rr sync FET and tune dead time tightly.