Why switching loss dominates the high-side buck MOSFET
In a high step-down buck converter (such as 48 V to 12 V at 25% duty cycle), the high-side control MOSFET conducts for only a quarter of the cycle—keeping I²R conduction loss modest—while absorbing hard-switched 48 V turn-on and turn-off transitions on every single clock edge.
Use this preset to verify whether a lower gate-charge (faster tr/tf) MOSFET with slightly higher R_DS(on) runs cooler than a giant low-R_DS(on) device.
Formulas
P_cond = 10² × (0.012 × 1.4) × 0.25 = 0.42 WP_sw = 0.5 × 48 × 10 × 32 ns × 100 kHz = 0.77 WTotal loss = 1.19 W (65% from switching!)
Worked example