USB-C PD 100W (20V 5A) VBUS PCB Trace Width Calculator

Size VBUS and GND PCB traces for 20 V 5 A USB-C Power Delivery (100 W), checking copper temperature rise and connector-to-regulator voltage drop.

Jump to results

Inputs

Current & thermal budget
Common baseline is 10 °C; power boards often allow 20–30 °C.
Board stackup & trace drop
Applies in IPC-2152 mode to account for copper plane heat spreading.

Results

Estimates
Minimum PCB trace width34.8 mil (0.88 mm)
Trace resistance
10.9 mΩ
Voltage drop
54.5 mV (0.27%)
Copper power loss
272.6 mW
Cross-sectional area
0.0619 mm² (95.9 mil²)
Operating copper temp
50 °C (80.8 A/mm²)
Internal equivalent
55.3 mil (1.41 mm)
PCB copper cross-section & weight comparison
W = 34.8 mil (0.88 mm)FR-4 Core (External Layer)t = 70 µm (2 oz)Reference Ground Plane (IPC2152) 0.5 oz (external) 139.2 mil · 3.54 mm 1 oz (external) 69.6 mil · 1.77 mm 2 oz (external) 34.8 mil · 0.88 mm 3 oz (external) 23.2 mil · 0.59 mm
Copper weight & layer comparison
CopperLayerWidth (mil)Width (mm)R (mΩ)Drop (mV)Loss (mW)
0.5 ozexternal139.23.5410.954.5272.6
0.5 ozinternal221.45.626.8534.3171.4
1 ozexternal69.61.7710.954.5272.6
1 ozinternal110.72.816.8534.3171.4
2 ozexternal34.80.8810.954.5272.6
2 ozinternal55.31.416.8534.3171.4
3 ozexternal23.20.5910.954.5272.6
3 ozinternal36.90.946.8534.3171.4

Calculated using IPC2152 at 50 °C copper temperature. Add copper pour or thermal vias if board airflow is restricted.

Route 20 V 5 A VBUS traces from USB-C receptacles safely

USB-C Power Delivery at 100 W pushes 5 A continuously through four paralleled VBUS pins and four GND pins on a compact receptacle. Tight pin pitch near the connector forces a short neck-down before fanning out into wide power pours or multi-layer vias.

Modeling VBUS at 35 °C enclosure ambient and 20 V rail voltage verifies that both temperature rise and percentage voltage drop remain negligible between the receptacle, eFuse/load switch and buck converter.

Formulas

  • P_bus = 20 V × 5 A = 100 W
  • Drop (%) = 100 × (5 A × R_trace) ÷ 20 V
  • Neck-down rule: keep short fanout < 3 mm and stitch vias immediately

Worked example

On 2 oz external copper (4-layer solid plane, 15 °C rise), 5 A requires ~34.9 mil (0.89 mm). A 35 mm VBUS run adds ~10.8 mΩ, dropping only 54 mV (0.27% of 20 V).

Frequently asked questions

How many vias are needed to carry 5 A from USB-C VBUS to an inner plane?

A standard 0.3 mm drill / 0.6 mm pad via with 25 µm plating handles roughly 1.0–1.5 A with minimal heating; use a cluster of 5–6 vias in parallel for 5 A VBUS.

Do I need 2 oz copper for USB-C 100 W?

No, 1 oz copper works well if you pour a ~2.0–2.5 mm wide polygon on top and mirror it on an inner power layer, though 2 oz simplifies narrow board routing.

What about USB-C PD 240 W EPR (48 V 5 A)?

Current remains capped at 5 A for EPR, so copper width stays identical, but conductor-to-conductor clearance must increase for 48 V working voltage and surge protection.