Structures

Ogee Spillway & Sluice Gate Calculator

Estimate free ogee overflow or free and submerged sluice-gate underflow. Export downstream crest coordinates and check low-pressure exposure.

Results ↓

Inputs

Control type
Overflow crest
m
m
m
m
Crest height over the upstream approach invert.

Hydraulic readout

Free overflow

Discharge: 33.7685 m³/s, Head ratio: 1.14783, C / Cᵈ: 1.02217, Coefficient: 2.22665 m½/s

Ogee crest section and discharge coefficientDownstream coordinates are plotted with a scaled crest profile. The chart marks the current operating head ratio and the pressure screen.DISCHARGE33.769 m³/sHEAD RATIO1.1478C / Cᵈ1.0222COEFFICIENT2.2266 m½/sOverflow profileNappeOgeeHₑ & POperating coefficient C/CᵈChart fitWarningHₑ/Hᵈ →Operating head ratio1.1478 / 1.33
  • Width is effective after pier and abutment contractions. The rating assumes a vertical upstream face and unimpeded overflow.

Calculation details

Design coefficient
2.17834 m½/s
Effective crest width
10 m
Design energy head
1.15 m
Operating energy head
1.32 m
Apron depth
3.2 m

Downstream ogee crest coordinates

X / HᵈStation XmDrop Ym
000
0.250.28750.044244
0.50.5750.1595
0.750.86250.3377
11.150.575
1.251.43750.86886
1.51.7251.2174
1.752.01251.6192
22.32.0729
2.252.58752.5775
2.52.8753.1323

Calculation method

Qogee = C L Hₑ³ᐟ² · X¹·⁸⁵ = 2 Hᵈ⁰·⁸⁵ Y · y₂ = C꜀ a

The vertical-face ogee coefficient uses rounded readings from Design of Small Dams Figures 9-23 and 9-24. The gate compares tailwater against the free jet’s conjugate depth and switches to a continuous differential-head relation.

Ogee overflow assumes unimpeded discharge. Very low or high heads, pier geometry and downstream suppression require additional checks. Confirm actual gate ratings against field or model data.

Worked examples