Worked example

Ogee overflow at design head

A 12 m effective crest operates at its 1.4 m design energy head with 4.7 m of upstream apron depth.

Results ↓

Inputs

Control type
Overflow crest
m
m
m
m
Crest height over the upstream approach invert.

Hydraulic readout

Free overflow

Discharge: 43.3489 m³/s, Head ratio: 1, C / Cᵈ: 1, Coefficient: 2.18074 m½/s

Ogee crest section and discharge coefficientDownstream coordinates are plotted with a scaled crest profile. The chart marks the current operating head ratio and the pressure screen.DISCHARGE43.349 m³/sHEAD RATIO1C / Cᵈ1COEFFICIENT2.1807 m½/sOverflow profileNappeOgeeHₑ & POperating coefficient C/CᵈChart fitWarningHₑ/Hᵈ →Operating head ratio1 / 1.33
  • Width is effective after pier and abutment contractions. The rating assumes a vertical upstream face and unimpeded overflow.

Calculation details

Design coefficient
2.18074 m½/s
Effective crest width
12 m
Design energy head
1.4 m
Operating energy head
1.4 m
Apron depth
4.7 m

Downstream ogee crest coordinates

X / HᵈStation XmDrop Ym
000
0.250.350.053863
0.50.70.19417
0.751.050.41111
11.40.7
1.251.751.0577
1.52.11.4821
1.752.451.9711
22.82.5235
2.253.153.1379
2.53.53.8132

Interpreting this example

C/Cᵈ equals 1 at design head. Inspect the normalized crest coordinates before converting into site station and elevation.

Qogee = C L Hₑ³ᐟ² · X¹·⁸⁵ = 2 Hᵈ⁰·⁸⁵ Y · y₂ = C꜀ a

The vertical-face ogee coefficient uses rounded readings from Design of Small Dams Figures 9-23 and 9-24. The gate compares tailwater against the free jet’s conjugate depth and switches to a continuous differential-head relation.

Ogee overflow assumes unimpeded discharge. Very low or high heads, pier geometry and downstream suppression require additional checks. Confirm actual gate ratings against field or model data.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet