Structures
Ogee Spillway & Sluice Gate Calculator
Estimate free ogee overflow or free and submerged sluice-gate underflow. Export downstream crest coordinates and check low-pressure exposure.
Inputs
Hydraulic readout
Free overflow
Discharge: 33.7685 m³/s, Head ratio: 1.14783, C / Cᵈ: 1.02217, Coefficient: 2.22665 m½/s
Input values
- Structure
- Ogee spillway
- Effective crest width L
- 10 m
- Design energy head Hᵈ
- 1.15 m
- Operating energy head Hₑ
- 1.32 m
- Upstream apron depth P
- 3.2 m
- Width is effective after pier and abutment contractions. The rating assumes a vertical upstream face and unimpeded overflow.
Calculation details
- Design coefficient
- 2.17834 m½/s
- Effective crest width
- 10 m
- Design energy head
- 1.15 m
- Operating energy head
- 1.32 m
- Apron depth
- 3.2 m
Downstream ogee crest coordinates
| X / Hᵈ | Station Xm | Drop Ym |
|---|---|---|
| 0 | 0 | 0 |
| 0.25 | 0.2875 | 0.044244 |
| 0.5 | 0.575 | 0.1595 |
| 0.75 | 0.8625 | 0.3377 |
| 1 | 1.15 | 0.575 |
| 1.25 | 1.4375 | 0.86886 |
| 1.5 | 1.725 | 1.2174 |
| 1.75 | 2.0125 | 1.6192 |
| 2 | 2.3 | 2.0729 |
| 2.25 | 2.5875 | 2.5775 |
| 2.5 | 2.875 | 3.1323 |
Calculation method
Qogee = C L Hₑ³ᐟ² · X¹·⁸⁵ = 2 Hᵈ⁰·⁸⁵ Y · y₂ = C꜀ a
The vertical-face ogee coefficient uses rounded readings from Design of Small Dams Figures 9-23 and 9-24. The gate compares tailwater against the free jet’s conjugate depth and switches to a continuous differential-head relation.
Ogee overflow assumes unimpeded discharge. Very low or high heads, pier geometry and downstream suppression require additional checks. Confirm actual gate ratings against field or model data.
Worked examples
Open a case to load its inputs and interpretation.
- Ogee overflow at design headA 12 m effective crest operates at its 1.4 m design energy head with 4.7 m of upstream apron depth.
- Ogee crest with a shallow approachA 24 ft vertical-face overflow crest stands 1.6 ft above the approach invert. Both design and operating energy heads are 5.5 ft.
- Overflow above the design headA 16 m spillway shaped for a 1.7 m design head experiences a 2.4 m total energy head.
- Free sluice underflowA 2.8 m turnout gate is raised 0.32 m under a 2.45 m upstream pool. Tailwater is 0.44 m deep.
- Drowned sluice in a control bayA 3.6 m gate has an 0.48 m opening, 3.15 m upstream depth and 2.6 m receiving-pool depth.
- Low head difference at a sluiceTwo pools separated by a 5 ft gate have depths of 8.2 ft and 8.0 ft. The opening is 0.9 ft.