Worked example

HEC-18 20° skewed pier

Apply a 20° flow angle to the FHWA simple solid pier example. The total length is 59 ft and the width is 4 ft.

Results ↓

Inputs

Assessment
Approach & pier geometry
ft
ft/s
ft
ft
Pier alignment
°

Hydraulic readout

Local scour reaches footing

Local scour: 28.2324 ft, Footing cover: -10.2324 ft, Froude: 0.608315, Skew factor K₂: 2.86286

Local pier scour section and flow attack angleThe local scour hollow and footing cover are drawn relative to the original bed. The plan sketch rotates the pier to the given angle of attack.LOCAL SCOUR28.232 ftFOOTING COVER-10.232 ftFROUDE0.60832SKEW FACTOR K₂2.8629Horseshoe vortex & scour holeWaterScour yₛFootingPier plan · approach flowApproachAxisPierLocal scour / original cover28.232 ft / 18 ft
  • HEC-18 local pier scour only. Add contraction scour and long-term bed change to evaluate total scour. Use the raw CSU estimate and geometry checks when reviewing the aligned-pier cap.
  • L/a is capped at 12 for K₂. Check actual exposed pier length and flow shielding.

Calculation details

Raw CSU scour depth
28.2324 ft
Original footing cover
18 ft
Pier nose factor K₁
1
Bed condition factor K₃
1.1

Interpreting this example

HEC-18 caps L/a at 12 for K₂. Local scour grows to roughly 28 ft in this worked example, so the footing needs further review.

τ₀ = ρg Rₕ S₀ · θ = τ₀/[ρ (Gₛ − 1)g d₅₀] · yₛ/y₁ = 2 K₁ K₂ K₃ (a/y₁)⁰·⁶⁵ Fr₁⁰·⁴³

The sediment mode compares applied Shields stress with the Soulsby–Whitehouse critical curve. The pier mode applies HEC-18 Equation 7.1 and the angle and nose-factor rules. The aligned rounded-pier rule of thumb is shown alongside raw CSU scour.

Treat these estimates as local screening results. The pier mode needs a separate evaluation of contraction, degradation, debris, complex foundations and cohesive or rock beds.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet