Wall shear 2,066 s⁻¹
Apparent shear 1,503 s⁻¹
Pressure drop 9.631 MPa
Wall viscosity 128.174 Pa·s
Velocity profile through the gate or runner Live schematic
FLOW PROFILE ROUND SECTION Land 50 mm Ø 5.5 mm Q 24.55 cm³/s ΔP 9.631 MPa
Within resin shear limit
0% 100% limit 125%+
The wide-slit model assumes negligible sidewall effects. A shear-limit check screens for possible splay, burn marks and degradation.
Share link Reset defaults JSON CSV SVG PNG (2×) Print A4
Calculation details
Volume flow through one channel 24.55 cm³/s Rabinowitsch factor 1.375× Resin wall-shear limit 18,000 s⁻¹ Shear rate below limit 15,934 s⁻¹ Shear limit used 11.5% Slit width to gap Round channel
Working through the example
The runner diameter governs shear with a cubic dependence. The land pressure drop uses corrected wall stress.
Round γ_app = 32Q/(πD³), correction (3n+1)/(4n). Slit γ_app = 6Q/(wh²), correction (2n+1)/(3n). η = Kγ_w^(n−1).
Use flow per gate or runner and consistent temperature-specific K and n. The pressure drop is wall stress times 4L/D for the round channel or 2L/h for the wide slit. This assumes isothermal, fully developed, no-slip flow and omits entry loss. Aspect ratios below 5:1 require a finite-width check. The supported power-law index is 0.1 < n ≤ 1.
Methodology and sources
τ_w = Kγ_wⁿ · ΔP = τ_w × (4L/D or 2L/h)
Inputs Channel geometry Circular runner Runner diameter 5.5 mm Channel land length 50 mm Fill volume through one channel 27 cm³ Fill time 1.1 s Power-law consistency K 12,500 Pa·sⁿ Power-law flow index n 0.4 Resin wall-shear limit 18,000 s⁻¹
Results Wall shear 2,066 s⁻¹ Apparent shear 1,503 s⁻¹ Pressure drop 9.631 MPa Wall viscosity 128.174 Pa·s Volume flow through one channel 24.55 cm³/s Rabinowitsch factor 1.375× Resin wall-shear limit 18,000 s⁻¹ Shear rate below limit 15,934 s⁻¹ Shear limit used 11.5% Slit width to gap Round channel
Within resin shear limit. The wide-slit model assumes negligible sidewall effects. A shear-limit check screens for possible splay, burn marks and degradation.
FLOW PROFILE ROUND SECTION Land 50 mm Ø 5.5 mm Q 24.55 cm³/s ΔP 9.631 MPa
Use flow per gate or runner and consistent temperature-specific K and n. The pressure drop is wall stress times 4L/D for the round channel or 2L/h for the wide slit. This assumes isothermal, fully developed, no-slip flow and omits entry loss. Aspect ratios below 5:1 require a finite-width check. The supported power-law index is 0.1 < n ≤ 1.