Steel flow 114.5729 mm
Steel cross 68.3417 mm
Worst error 0.1001 mm
Shrink delta 0 pp
Steel and molded-part dimension overlay Live schematic
STEEL ENVELOPE MOLDED OUTLINE Flow 114.573 mm Cross 68.342 mm
Within part tolerance
0% 100% tolerance 125%+
Compares the largest absolute error from the two worst-case bands. Directional shrink difference indicates warpage tendency.
Share link Reset defaults JSON CSV SVG PNG (2×) Print A4
Calculation details
Selected convention Mold basis · Lₚ ÷ (1 − S) Flow molded minimum 113.8999 mm Flow molded maximum 114.1001 mm Cross molded minimum 67.9323 mm Cross molded maximum 68.0678 mm Part tolerance remaining 0.0199 mm Directional shrink No difference entered
Working through the example
Calculate steel by dividing each part target by 0.995. The longer flow dimension has a wider absolute band.
Mold basis S = (L_cav−L_part)/L_cav. Part basis S = (L_cav−L_part)/L_part. Use the same basis for the steel calculation and its inverse.
Apply the shrinkage spread in percentage points and the steel tolerance as an absolute ± dimension. The low end uses the smallest steel and greatest shrink. The high end uses the largest steel and least shrink. Compare the greatest deviation from either nominal dimension with the part tolerance. Resin presets illustrate directional inputs. Confirm values for the actual grade, flow direction, processing and conditioning.
Methodology and sources
L_cav = L_part ÷ (1 − S) or L_part × (1 + S)
Inputs Nominal size in flow 114 mm Nominal size in cross-flow 68 mm Directional shrinkage preset ABS · 0.5% / 0.5% Flow shrinkage 0.5 % Cross-flow shrinkage 0.5 % Shrinkage convention Mold basis · divide by (1 − S) Shrinkage process spread ± 0.07 pp Steel machining tolerance ± 0.02 mm Target part tolerance ± 0.12 mm
Results Steel flow 114.5729 mm Steel cross 68.3417 mm Worst error 0.1001 mm Shrink delta 0 pp Selected convention Mold basis · Lₚ ÷ (1 − S) Flow molded minimum 113.8999 mm Flow molded maximum 114.1001 mm Cross molded minimum 67.9323 mm Cross molded maximum 68.0678 mm Part tolerance remaining 0.0199 mm Directional shrink No difference entered
Within part tolerance. Compares the largest absolute error from the two worst-case bands. Directional shrink difference indicates warpage tendency.
STEEL ENVELOPE MOLDED OUTLINE Flow 114.573 mm Cross 68.342 mm
Apply the shrinkage spread in percentage points and the steel tolerance as an absolute ± dimension. The low end uses the smallest steel and greatest shrink. The high end uses the largest steel and least shrink. Compare the greatest deviation from either nominal dimension with the part tolerance. Resin presets illustrate directional inputs. Confirm values for the actual grade, flow direction, processing and conditioning.