ABS shot larger than the rated barrel

A 150 cm³ shot has been proposed for a 100 cm³ rated injection unit.

Edit inputs ↓

Inputs

cm³
cm³
×
2.0–2.5 is a starting point. Use machine data if available.
s
min
Review calculations ↑
Residence
1.33min
Barrel cycles
1.33
Melt inventory
200cm³
Time margin
6.67min

Barrel inventory and shot withdrawal

Live schematic
HEATED BARREL2× RATEDHold-up 1.33 cyclesShot 150 cm³

Shot exceeds rated capacity

0%100% ceiling125%+

The threshold applies to the estimated average residence time. Stagnant melt can stay in the barrel longer.

Calculation details
Shot through barrel150 cm³
Rated barrel capacity100 cm³
Inventory multiplier2×
Cycle time60 s
Thermal ceiling8 min
Ceiling used16.7%

Working through the example

The short calculated residence does not make the shot feasible. The required volume exceeds the rated barrel.

V_inventory = K_inv × V_rated. Cycles in barrel = V_inventory/V_shot. t_res (min) = cycles × t_cycle (s)/60.

Use the average running cycle and the melt volume actually discharged per cycle. The 2.0–2.5 inventory multiplier and resin ceilings are screening inputs. Screw design, idle periods, melt temperature and material held in dead spots can change the residence-time distribution.

Methodology and sources