PP trial with a custom residence ceiling

The trial team uses its own 4.2-minute average residence screen.

Edit inputs ↓

Inputs

cm³
cm³
×
2.0–2.5 is a starting point. Use machine data if available.
s
min
Review calculations ↑
Residence
4.11min
Barrel cycles
5.49
Melt inventory
576cm³
Time margin
0.09min

Barrel inventory and shot withdrawal

Live schematic
HEATED BARREL2.4× RATEDHold-up 5.49 cyclesShot 105 cm³

Within residence ceiling

0%100% ceiling125%+

The threshold applies to the estimated average residence time. Stagnant melt can stay in the barrel longer.

Calculation details
Shot through barrel105 cm³
Rated barrel capacity240 cm³
Inventory multiplier2.4×
Cycle time45 s
Thermal ceiling4.2 min
Ceiling used98%

Working through the example

The 576 cm³ inventory turns over in about five and a half cycles. Compare that time with the custom ceiling.

V_inventory = K_inv × V_rated. Cycles in barrel = V_inventory/V_shot. t_res (min) = cycles × t_cycle (s)/60.

Use the average running cycle and the melt volume actually discharged per cycle. The 2.0–2.5 inventory multiplier and resin ceilings are screening inputs. Screw design, idle periods, melt temperature and material held in dead spots can change the residence-time distribution.