The cross-minus-flow result is negative. The directional difference helps flag warpage sensitivity without estimating a deflection.
Mold basis S = (L_cav−L_part)/L_cav. Part basis S = (L_cav−L_part)/L_part. Use the same basis for the steel calculation and its inverse.
Apply the shrinkage spread in percentage points and the steel tolerance as an absolute ± dimension. The low end uses the smallest steel and greatest shrink. The high end uses the largest steel and least shrink. Compare the greatest deviation from either nominal dimension with the part tolerance. Resin presets illustrate directional inputs. Confirm values for the actual grade, flow direction, processing and conditioning.