PA66-GF30 connector with directional shrink

The cross-flow shrinkage exceeds the flow shrinkage for the filled nylon grade.

Edit inputs ↓

Inputs

mm
mm
%
%
pp
Percentage points added to and subtracted from each nominal shrinkage.
mm
mm
Review calculations ↑
Steel flow
78.3133mm
Steel cross
41.3724mm
Worst error
0.1239mm
Shrink delta
0.5pp

Steel and molded-part dimension overlay

Live schematic
STEEL ENVELOPEMOLDED OUTLINEFlow 78.313 mmCross 41.372 mm

Predicted band exceeds tolerance

0%100% tolerance125%+

Compares the largest absolute error from the two worst-case bands. Directional shrink difference indicates warpage tendency.

Calculation details
Selected conventionMold basis · Lₚ ÷ (1 − S)
Flow molded minimum77.8762 mm
Flow molded maximum78.1239 mm
Cross molded minimum40.9207 mm
Cross molded maximum41.0794 mm
Part tolerance remaining-0.0239 mm
Directional shrinkCross-flow shrinks more

Working through the example

Calculate flow and cross-flow steel independently. The flow tolerance band exceeds the drawing even with smaller nominal shrinkage.

Mold basis S = (L_cav−L_part)/L_cav. Part basis S = (L_cav−L_part)/L_part. Use the same basis for the steel calculation and its inverse.

Apply the shrinkage spread in percentage points and the steel tolerance as an absolute ± dimension. The low end uses the smallest steel and greatest shrink. The high end uses the largest steel and least shrink. Compare the greatest deviation from either nominal dimension with the part tolerance. Resin presets illustrate directional inputs. Confirm values for the actual grade, flow direction, processing and conditioning.

Methodology and sources