Glass-filled nylon bracket clamp check

A four-impression bracket tool uses the higher cavity-pressure tier for filled nylon.

Edit inputs ↓

Inputs

cm²
cm²
Total for one shot, including the projected feed system.
MPa
×
Range 1.10–1.25.
metric t
Review calculations ↑
Clamp force
55.94metric t
Projected area
78cm²
Press use
87.1%
Clamp reserve
8.31metric t

Projected area at the parting plane

Live schematic
4 × CAVITIES58.6 MPaArea 78 cm²Runner 6 cm²

Within press rating

0%100% rating125%+

Includes the entered safety factor. The rating boundary is 100% utilization.

Calculation details
Required clamp force548.55 kN
Required clamp force61.66 US tons
Required clamp force55.94 metric t
Installed press rating64.24 metric t
Cavity pressure58.61 MPa
Reserve of installed rating12.9%

Working through the example

The part and runner together project 78 cm². The higher cavity pressure still leaves a positive reserve on this press.

A_proj = N × A_part + A_runner. F_required (kN) = 0.1 × A_proj (cm²) × P_cavity (MPa) × SF.

Use the silhouette in the clamp direction, including the projected feed system. Enter mean cavity pressure at the limiting fill or packing condition. The pressure tiers are starting estimates. Use a measured or simulated cavity pressure for press selection when available. The utilization boundary compares the calculated force with the entered rating.