POM on a 20-second cycle

A high-throughput tool takes a 110 cm³ shot from a moderate barrel.

Edit inputs ↓

Inputs

cm³
cm³
×
2.0–2.5 is a starting point. Use machine data if available.
s
min
Review calculations ↑
Residence
1.39min
Barrel cycles
4.18
Melt inventory
460cm³
Time margin
3.61min

Barrel inventory and shot withdrawal

Live schematic
HEATED BARREL2× RATEDHold-up 4.18 cyclesShot 110 cm³

Within residence ceiling

0%100% ceiling125%+

The threshold applies to the estimated average residence time. Stagnant melt can stay in the barrel longer.

Calculation details
Shot through barrel110 cm³
Rated barrel capacity230 cm³
Inventory multiplier2×
Cycle time20 s
Thermal ceiling5 min
Ceiling used27.9%

Working through the example

Divide estimated melt inventory by shot volume before converting the corresponding cycles to minutes.

V_inventory = K_inv × V_rated. Cycles in barrel = V_inventory/V_shot. t_res (min) = cycles × t_cycle (s)/60.

Use the average running cycle and the melt volume actually discharged per cycle. The 2.0–2.5 inventory multiplier and resin ceilings are screening inputs. Screw design, idle periods, melt temperature and material held in dead spots can change the residence-time distribution.

Methodology and sources