Residence 5.94 min
Barrel cycles 13.71
Melt inventory 480 cm³
Time margin -2.94 min
Barrel inventory and shot withdrawal Live schematic
HEATED BARREL 2.4× RATED Hold-up 13.71 cycles Shot 35 cm³
Residence ceiling exceeded
0% 100% ceiling 125%+
The threshold applies to the estimated average residence time. Stagnant melt can stay in the barrel longer.
Share link Reset defaults JSON CSV SVG PNG (2×) Print A4
Calculation details
Shot through barrel 35 cm³ Rated barrel capacity 200 cm³ Inventory multiplier 2.4× Cycle time 26 s Thermal ceiling 3 min Ceiling used 198.1%
Working through the example
The nominal 480 cm³ inventory takes nearly fourteen cycles to turn over. The average time exceeds the 3-minute screen.
V_inventory = K_inv × V_rated. Cycles in barrel = V_inventory/V_shot. t_res (min) = cycles × t_cycle (s)/60.
Use the average running cycle and the melt volume actually discharged per cycle. The 2.0–2.5 inventory multiplier and resin ceilings are screening inputs. Screw design, idle periods, melt temperature and material held in dead spots can change the residence-time distribution.
Methodology and sources
t_res = (K_inv × V_max ÷ V_shot) × t_cyc
Inputs Shot input basis Melt volume Shot melt volume 35 cm³ Rated barrel volume 200 cm³ Barrel inventory multiplier 2.4 × Cycle time 26 s Thermal ceiling preset Rigid PVC · 3 min Thermal residence ceiling 3 min
Results Residence 5.94 min Barrel cycles 13.71 Melt inventory 480 cm³ Time margin -2.94 min Shot through barrel 35 cm³ Rated barrel capacity 200 cm³ Inventory multiplier 2.4× Cycle time 26 s Thermal ceiling 3 min Ceiling used 198.1%
Residence ceiling exceeded. The threshold applies to the estimated average residence time. Stagnant melt can stay in the barrel longer.
HEATED BARREL 2.4× RATED Hold-up 13.71 cycles Shot 35 cm³
Use the average running cycle and the melt volume actually discharged per cycle. The 2.0–2.5 inventory multiplier and resin ceilings are screening inputs. Screw design, idle periods, melt temperature and material held in dead spots can change the residence-time distribution.