Rigid PVC in a large barrel

A 35 cm³ shot withdraws material slowly from a 200 cm³ rated barrel.

Edit inputs ↓

Inputs

cm³
cm³
×
2.0–2.5 is a starting point. Use machine data if available.
s
min
Review calculations ↑
Residence
5.94min
Barrel cycles
13.71
Melt inventory
480cm³
Time margin
-2.94min

Barrel inventory and shot withdrawal

Live schematic
HEATED BARREL2.4× RATEDHold-up 13.71 cyclesShot 35 cm³

Residence ceiling exceeded

0%100% ceiling125%+

The threshold applies to the estimated average residence time. Stagnant melt can stay in the barrel longer.

Calculation details
Shot through barrel35 cm³
Rated barrel capacity200 cm³
Inventory multiplier2.4×
Cycle time26 s
Thermal ceiling3 min
Ceiling used198.1%

Working through the example

The nominal 480 cm³ inventory takes nearly fourteen cycles to turn over. The average time exceeds the 3-minute screen.

V_inventory = K_inv × V_rated. Cycles in barrel = V_inventory/V_shot. t_res (min) = cycles × t_cycle (s)/60.

Use the average running cycle and the melt volume actually discharged per cycle. The 2.0–2.5 inventory multiplier and resin ceilings are screening inputs. Screw design, idle periods, melt temperature and material held in dead spots can change the residence-time distribution.