Shot weight 152 g
Melt volume 170.79 cm³
Dose stroke 107.38 mm
Barrel use 53.7 %
Screw stroke and melt cushion Live schematic
SCREW Ø 45 mm MAX 200 mm Dose 107.38 mm Cushion 5 mm
Within 20–80% window
<20% 20–80% >80%
Below 20% raises residence-time risk. Above 80% can restrict consistent plasticizing. The cushion also has to fit.
Share link Reset defaults JSON CSV SVG PNG (2×) Print A4
Calculation details
Rated swept volume 318.09 cm³ Equivalent solid volume 144.76 cm³ Cushion volume 7.95 cm³ Dose plus cushion 112.38 mm Stroke remaining 87.62 mm Melt density 0.89 g/cm³
Model and assumptions
m_shot = N × m_part + m_runner. V_melt = m_shot/ρ_melt. S_dose = 1000V_melt/(πD²/4) with cm³ and mm.
The barrel rating is geometric swept volume. Utilization counts the dose only, with 20–80% inclusive. Add the target cushion separately for the travel check. The solid-density result gives an equivalent room-temperature volume. Material and machine limits can narrow the screening window.
Methodology and sources
S_dose = V_shot ÷ (πD²/4)
Inputs Cavities 4 Net part mass 35 g Runner and sprue mass per shot 12 g Solid resin density 1.05 g/cm³ Melt resin density 0.89 g/cm³ Screw diameter 45 mm Maximum screw stroke 200 mm Target cushion stroke 5 mm
Results Shot weight 152 g Melt volume 170.79 cm³ Dose stroke 107.38 mm Barrel use 53.7% Rated swept volume 318.09 cm³ Equivalent solid volume 144.76 cm³ Cushion volume 7.95 cm³ Dose plus cushion 112.38 mm Stroke remaining 87.62 mm Melt density 0.89 g/cm³
Within 20–80% window. Below 20% raises residence-time risk. Above 80% can restrict consistent plasticizing. The cushion also has to fit.
SCREW Ø 45 mm MAX 200 mm Dose 107.38 mm Cushion 5 mm
The barrel rating is geometric swept volume. Utilization counts the dose only, with 20–80% inclusive. Add the target cushion separately for the travel check. The solid-density result gives an equivalent room-temperature volume. Material and machine limits can narrow the screening window.