Continuous Full Load With No Pressure Change

Check the 100% load limit where all three control curves converge.

Inputs

View results ↓
Compressor and pressure
SCFM
kW
%
psig
psi
Annual load profile

Enter two time shares. The third load level fills the rest of the operating year.

%
%
%
%
%
h/yr
Electricity and investment
USD/kWh
USD

Results

Edit inputs ↑
Part-load compressor power curves SPEC. POWER 18.8 kW/100 SCFMBASE ENERGY 7.7e5 kWh/yrSAVINGS 0 USD/yrPAYBACK — yr POWER / FULL LOAD 0% 100% LOAD MODULATE LOAD/UNLOAD VFD PROFILE MEAN LOAD 100 % 0% 25% VFD KNEE 100%
Part-load compressor power curves
Full-load specific power
18.8 kW/100 SCFM
Existing annual electricity
770,800 kWh/yr
Combined annual savings
0 USD/yr
Simple payback
—
Full-load package power
94 kW
Equivalent shaft power
119.75 hp
Weighted mean load
100 %
Time at load level 3
0 %
Inlet modulation annual energy
770,800 kWh/yr
Load/unload annual energy
770,800 kWh/yr
VFD annual energy at existing pressure
770,800 kWh/yr
VFD annual energy at lower pressure
770,800 kWh/yr
Existing annual electricity cost
84,788 USD/yr
Upgraded annual electricity cost
84,788 USD/yr
Savings from VFD only
0 USD/yr
Additional pressure savings
0 USD/yr
Power reduction at new pressure
0 %

Formula and assumptions

Set the full-load basis

Package kW ≈ shaft hp × 0.7457 ÷ motor efficiency · specific power = package kW/rated flow

A measured full-load package draw is preferred. The motor-mode estimate treats the entered shaft rating as full-load shaft power and omits separate auxiliary loads. Match flow reference, pressure, and package boundaries when comparing ISO 1217 or CAGI performance sheets.

Weight the part-load curves

Annual kWh = full-load kW × hours × Σ(time share × power ratio)

At fractional load L the planning curves are 0.70 + 0.30L for inlet modulation, 0.30 + 0.70L for load/unload, and 0.12 + 0.88L for VFD at or above 25% load. Below 25% the VFD model averages minimum-speed operation with 6% standby draw. Use actual package curves for a purchase decision.

Estimate pressure savings and payback

Pressure factor = 1 − 0.005 × reduction in psi · payback = installed cost/annual savings

The DOE rule of thumb is about 1% of full-output power per 2 psi near 100 psig. The model applies the same factor to the VFD scenario, with rated flow held constant. It excludes demand charges, service costs, and air demand changes after lowering pressure.

Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.

Worked examples