Pressure-Only VFD Optimization
Estimate the pressure-reduction benefit for a compressor that already uses variable speed.
Inputs
View results ↓Results
Edit inputs ↑- Full-load specific power
- 19.024 kW/100 SCFM
- Existing annual electricity
- 315,600 kWh/yr
- Combined annual savings
- 2,367 USD/yr
- Simple payback
- 0.92945 yr
- Full-load package power
- 78 kW
- Equivalent shaft power
- 99.37 hp
- Weighted mean load
- 57.1 %
- Time at load level 3
- 20 %
- Inlet modulation annual energy
- 441,750 kWh/yr
- Load/unload annual energy
- 354,750 kWh/yr
- VFD annual energy at existing pressure
- 315,600 kWh/yr
- VFD annual energy at lower pressure
- 296,660 kWh/yr
- Existing annual electricity cost
- 39,450 USD/yr
- Upgraded annual electricity cost
- 37,083 USD/yr
- Savings from VFD only
- 0 USD/yr
- Additional pressure savings
- 2,367 USD/yr
- Power reduction at new pressure
- 6 %
Formula and assumptions
Set the full-load basis
Package kW ≈ shaft hp × 0.7457 ÷ motor efficiency · specific power = package kW/rated flow
A measured full-load package draw is preferred. The motor-mode estimate treats the entered shaft rating as full-load shaft power and omits separate auxiliary loads. Match flow reference, pressure, and package boundaries when comparing ISO 1217 or CAGI performance sheets.
Weight the part-load curves
Annual kWh = full-load kW × hours × Σ(time share × power ratio)
At fractional load L the planning curves are 0.70 + 0.30L for inlet modulation, 0.30 + 0.70L for load/unload, and 0.12 + 0.88L for VFD at or above 25% load. Below 25% the VFD model averages minimum-speed operation with 6% standby draw. Use actual package curves for a purchase decision.
Estimate pressure savings and payback
Pressure factor = 1 − 0.005 × reduction in psi · payback = installed cost/annual savings
The DOE rule of thumb is about 1% of full-output power per 2 psi near 100 psig. The model applies the same factor to the VFD scenario, with rated flow held constant. It excludes demand charges, service costs, and air demand changes after lowering pressure.
Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.
Worked examples
-
Load/Unload to VFD Retrofit
Estimate VFD and pressure savings for a 76 kW compressor serving three production loads.
-
Modulated Screw Compressor Retrofit
Compare inlet modulation against a VFD for a large package with frequent light load.
-
75 hp Motor Nameplate Estimate
Estimate package electricity from a 75 hp shaft rating and 93% motor efficiency.
-
Pressure-Only VFD Optimization
Estimate the pressure-reduction benefit for a compressor that already uses variable speed.
-
Two-Shift Metric Compressor Package
Evaluate a 55 kW air compressor and compare the upgraded annual electricity cost in GBP.
-
Continuous Full Load With No Pressure Change
Check the 100% load limit where all three control curves converge.