Pressure-Only VFD Optimization

Estimate the pressure-reduction benefit for a compressor that already uses variable speed.

Inputs

View results ↓
Compressor and pressure
SCFM
kW
%
psig
psi
Annual load profile

Enter two time shares. The third load level fills the rest of the operating year.

%
%
%
%
%
h/yr
Electricity and investment
USD/kWh
USD

Results

Edit inputs ↑
Part-load compressor power curves SPEC. POWER 19.02 kW/100 SCFMBASE ENERGY 3.2e5 kWh/yrSAVINGS 2,367 USD/yrPAYBACK 0.9295 yr POWER / FULL LOAD 0% 100% LOAD MODULATE LOAD/UNLOAD VFD PROFILE MEAN LOAD 57.1 % 0% 25% VFD KNEE 100%
Part-load compressor power curves
Full-load specific power
19.024 kW/100 SCFM
Existing annual electricity
315,600 kWh/yr
Combined annual savings
2,367 USD/yr
Simple payback
0.92945 yr
Full-load package power
78 kW
Equivalent shaft power
99.37 hp
Weighted mean load
57.1 %
Time at load level 3
20 %
Inlet modulation annual energy
441,750 kWh/yr
Load/unload annual energy
354,750 kWh/yr
VFD annual energy at existing pressure
315,600 kWh/yr
VFD annual energy at lower pressure
296,660 kWh/yr
Existing annual electricity cost
39,450 USD/yr
Upgraded annual electricity cost
37,083 USD/yr
Savings from VFD only
0 USD/yr
Additional pressure savings
2,367 USD/yr
Power reduction at new pressure
6 %

Formula and assumptions

Set the full-load basis

Package kW ≈ shaft hp × 0.7457 ÷ motor efficiency · specific power = package kW/rated flow

A measured full-load package draw is preferred. The motor-mode estimate treats the entered shaft rating as full-load shaft power and omits separate auxiliary loads. Match flow reference, pressure, and package boundaries when comparing ISO 1217 or CAGI performance sheets.

Weight the part-load curves

Annual kWh = full-load kW × hours × Σ(time share × power ratio)

At fractional load L the planning curves are 0.70 + 0.30L for inlet modulation, 0.30 + 0.70L for load/unload, and 0.12 + 0.88L for VFD at or above 25% load. Below 25% the VFD model averages minimum-speed operation with 6% standby draw. Use actual package curves for a purchase decision.

Estimate pressure savings and payback

Pressure factor = 1 − 0.005 × reduction in psi · payback = installed cost/annual savings

The DOE rule of thumb is about 1% of full-output power per 2 psi near 100 psig. The model applies the same factor to the VFD scenario, with rated flow held constant. It excludes demand charges, service costs, and air demand changes after lowering pressure.

Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.

Worked examples