Subsonic Low-Pressure Leak
Check a small leak discharging from a 7 psig pneumatic branch.
Inputs
View results ↓Results
Edit inputs ↑- Free-air loss per orifice
- 2.9899 SCFM
- Total free-air loss
- 2.9899 SCFM
- Wasted power
- 0.65777 kW
- Annual electricity cost
- 368.35 USD/yr
- Annual electricity loss
- 2,631.1 kWh/yr
- Annual equivalent CO₂
- 2,320.2 lb CO₂/yr
- Ambient / inlet pressure ratio
- 0.67736
- Orifice flow regime
- Subsonic
Formula and assumptions
Find the flow regime
r = Pambient/Pin,abs · rcrit = (2/(γ + 1))^(γ/(γ − 1))
For dry air, γ = 1.4 and the sonic pressure ratio is about 0.528. Below that ratio the flow stays choked. The calculation assumes a short orifice venting to atmosphere and uses the pressure-dependent equation at lower header pressures.
Convert mass flow to free air
ṁ = Cd A Pin √(2γ[r^(2/γ) − r^((γ+1)/γ)]/((γ−1)RT))
Use the larger of r and the sonic ratio in this expression. Cd captures leak geometry. Divide mass flow by dry-air density at the selected volume reference to obtain standard flow. Multiply by leak count for the system loss.
Estimate electricity and CO₂
kW = total free-air flow × specific power · kWh/yr = kW × hours/yr
Multiply annual kWh by the entered tariff and grid emissions factor. Currency changes labels only. Actual savings depend on compressor control response, pressure, and how much of the leaked airflow can be removed from compressor output.
Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.
Worked examples
-
Three Small Header Leaks
Price three sharp-edged 1/16-inch leak openings on a 100 psig header.
-
Subsonic Low-Pressure Leak
Check a small leak discharging from a 7 psig pneumatic branch.
-
Smooth Nozzle Air Bleed
Estimate the annual cost of a continuous, smooth 3/32-inch nozzle opening.
-
Quick-Coupling Leak Audit
Compare 16 equivalent leaks found during a shift-change walkdown.
-
Metric Factory Leak Cost in EUR
Price two 2.4 mm leaks at 7.2 bar gauge with a euro-denominated tariff.
-
Isolated Header at Ambient
Check the limiting case with the isolated header fully depressurized.