Metric Factory Leak Cost in EUR

Price two 2.4 mm leaks at 7.2 bar gauge with a euro-denominated tariff.

Inputs

View results ↓
Leak geometry and air supply
mm
bar(g)
°C
Start at 0.65 for a sharp edge or 0.97 for a smooth nozzle.
Energy and emissions
kW/(Nm³/min)
h/yr
EUR/kWh
kg CO₂/kWh

Results

Edit inputs ↑
Annual leak cost by hole size PER LEAK 291.2 NL/minTOTAL LOSS 582.4 NL/minPOWER 4.135 kWCOST / YEAR 5,277 EUR/yr €577.2 0.79 mm €2,309 1.59 mm €9,234 3.18 mm €5,277 Your leak AMBIENT / INLET PRESSURE 0.1234 · Choked 0 0.528 SONIC 1.0
Annual leak cost by hole size
Free-air loss per orifice
291.21 NL/min
Total free-air loss
582.42 NL/min
Wasted power
4.1352 kW
Annual electricity cost
5,276.5 EUR/yr
Annual electricity loss
23,984 kWh/yr
Annual equivalent CO₂
5,756.2 kg CO₂/yr
Ambient / inlet pressure ratio
0.12337
Orifice flow regime
Choked

Formula and assumptions

Find the flow regime

r = Pambient/Pin,abs · rcrit = (2/(γ + 1))^(γ/(γ − 1))

For dry air, γ = 1.4 and the sonic pressure ratio is about 0.528. Below that ratio the flow stays choked. The calculation assumes a short orifice venting to atmosphere and uses the pressure-dependent equation at lower header pressures.

Convert mass flow to free air

ṁ = Cd A Pin √(2γ[r^(2/γ) − r^((γ+1)/γ)]/((γ−1)RT))

Use the larger of r and the sonic ratio in this expression. Cd captures leak geometry. Divide mass flow by dry-air density at the selected volume reference to obtain standard flow. Multiply by leak count for the system loss.

Estimate electricity and CO₂

kW = total free-air flow × specific power · kWh/yr = kW × hours/yr

Multiply annual kWh by the entered tariff and grid emissions factor. Currency changes labels only. Actual savings depend on compressor control response, pressure, and how much of the leaked airflow can be removed from compressor output.

Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.

Worked examples