Compressed Air Pipe Pressure Drop & Velocity Calculator
Estimate friction loss and actual line velocity for a straight compressed-air header with fittings.
Inputs
View results ↓Results
Edit inputs ↑- Pressure loss
- 0.4667 psi
- Outlet gauge pressure
- 99.533 psig
- Actual outlet velocity
- 13.913 ft/s4.2406 m/s
- Loss of inlet gauge pressure
- 0.4667 %
- Actual inlet velocity
- 13.856 ft/s
- Effective inside diameter
- 1.61 in
- Internal roughness used
- 1.7717 mil
- Reynolds number
- 88,902
- Darcy friction factor
- 0.022934
- Outlet Mach number
- 0.012331
Formula and assumptions
Convert free air to mass flow
ṁ = ρstd Qstd · G = ṁ/A · v = GRT/Pabs
SCFM and Nm³/min describe free air. Actual line velocity uses the local absolute pressure and entered air temperature. For presets, the model uses the displayed inside diameter and roughness. Confirm aluminum system IDs and fitting data with the manufacturer.
Calculate line pressure loss
Pout² = Pin² − f (L + Leq) G²RT/D
This integrates Darcy–Weisbach friction at constant temperature using absolute pressure, fixed diameter, and a Churchill Darcy factor. Fitting equivalent lengths use the same pipe diameter. The model neglects elevation and gas acceleration. Confirm cases where outlet Mach exceeds 0.25.
Screen the velocity and pressure budget
Pressure loss (%) = 100 × (Pin − Pout)/Pin,gauge
CAGI’s pressure-drop brief recommends 20 ft/s or lower. The diagram marks 20–30 ft/s as a screening band, with 30 ft/s as the upper mark. The 5% pressure-loss notice is a separate planning check.
Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.
Worked examples
-
90 SCFM Steel Main
Check a 1½-inch Schedule 40 header with 225 feet of total equivalent length.
-
Long Aluminum Distribution Run
Evaluate a smooth 63 mm-ID aluminum main serving several production cells.
-
Short Tool Air Branch
Test a ¾-inch steel branch feeding an intermittent industrial tool.
-
Aged Steel Pipe With Custom ID
Model a used header with a measured 1.96-inch bore and elevated internal roughness.
-
Large Ring Main Segment
Check one 3-inch steel ring segment at its assigned downstream demand.
-
Low-Flow Sensor Air Feed
Estimate loss in a narrow instrument feed at a small but continuous flow.