Large Ring Main Segment

Check one 3-inch steel ring segment at its assigned downstream demand.

Inputs

View results ↓
Flow and line conditions
SCFM
psig
°F
ft
ft
Pipe geometry

Results

Edit inputs ↑
Header pressure profile PRESS. LOSS 0.1466 psiOUTLET 114.9 psigVELOCITY 8.878 ft/sLOSS % 0.1275 % INLET OUTLET TOTAL RUN 337 ft ID 3.068 in OUTLET VELOCITY 8.878 ft/s 0 CAGI 20 ft/s UPPER 30 ft/s
Header pressure profile
Pressure loss
0.14658 psi
Outlet gauge pressure
114.85 psig
Actual outlet velocity
8.8778 ft/s2.706 m/s
Loss of inlet gauge pressure
0.12746 %
Actual inlet velocity
8.8678 ft/s
Effective inside diameter
3.068 in
Internal roughness used
1.7717 mil
Reynolds number
116,680
Darcy friction factor
0.020376
Outlet Mach number
0.0077598

Formula and assumptions

Convert free air to mass flow

ṁ = ρstd Qstd · G = ṁ/A · v = GRT/Pabs

SCFM and Nm³/min describe free air. Actual line velocity uses the local absolute pressure and entered air temperature. For presets, the model uses the displayed inside diameter and roughness. Confirm aluminum system IDs and fitting data with the manufacturer.

Calculate line pressure loss

Pout² = Pin² − f (L + Leq) G²RT/D

This integrates Darcy–Weisbach friction at constant temperature using absolute pressure, fixed diameter, and a Churchill Darcy factor. Fitting equivalent lengths use the same pipe diameter. The model neglects elevation and gas acceleration. Confirm cases where outlet Mach exceeds 0.25.

Screen the velocity and pressure budget

Pressure loss (%) = 100 × (Pin − Pout)/Pin,gauge

CAGI’s pressure-drop brief recommends 20 ft/s or lower. The diagram marks 20–30 ft/s as a screening band, with 30 ft/s as the upper mark. The 5% pressure-loss notice is a separate planning check.

Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.

Worked examples