Long Aluminum Distribution Run

Evaluate a smooth 63 mm-ID aluminum main serving several production cells.

Inputs

View results ↓
Flow and line conditions
Nm³/min
bar(g)
°C
m
m
Pipe geometry

Results

Edit inputs ↑
Header pressure profile PRESS. LOSS 0.01798 barOUTLET 6.982 bar(g)VELOCITY 3.096 m/sLOSS % 0.2568 % INLET OUTLET TOTAL RUN 140 m ID 63 mm OUTLET VELOCITY 3.096 m/s 0 CAGI 6.1 m/s UPPER 9.14 m/s
Header pressure profile
Pressure loss
0.017976 bar
Outlet gauge pressure
6.982 bar(g)
Actual outlet velocity
3.0959 m/s10.157 ft/s
Loss of inlet gauge pressure
0.2568 %
Actual inlet velocity
3.0889 m/s
Effective inside diameter
63 mm
Internal roughness used
1.5 μm
Reynolds number
99,762
Darcy friction factor
0.018028
Outlet Mach number
0.0089589

Formula and assumptions

Convert free air to mass flow

ṁ = ρstd Qstd · G = ṁ/A · v = GRT/Pabs

SCFM and Nm³/min describe free air. Actual line velocity uses the local absolute pressure and entered air temperature. For presets, the model uses the displayed inside diameter and roughness. Confirm aluminum system IDs and fitting data with the manufacturer.

Calculate line pressure loss

Pout² = Pin² − f (L + Leq) G²RT/D

This integrates Darcy–Weisbach friction at constant temperature using absolute pressure, fixed diameter, and a Churchill Darcy factor. Fitting equivalent lengths use the same pipe diameter. The model neglects elevation and gas acceleration. Confirm cases where outlet Mach exceeds 0.25.

Screen the velocity and pressure budget

Pressure loss (%) = 100 × (Pin − Pout)/Pin,gauge

CAGI’s pressure-drop brief recommends 20 ft/s or lower. The diagram marks 20–30 ft/s as a screening band, with 30 ft/s as the upper mark. The 5% pressure-loss notice is a separate planning check.

Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.

Worked examples