90 SCFM Steel Main

Check a 1½-inch Schedule 40 header with 225 feet of total equivalent length.

Inputs

View results ↓
Flow and line conditions
SCFM
psig
°F
ft
ft
Pipe geometry

Results

Edit inputs ↑
Header pressure profile PRESS. LOSS 0.4667 psiOUTLET 99.53 psigVELOCITY 13.91 ft/sLOSS % 0.4667 % INLET OUTLET TOTAL RUN 225 ft ID 1.61 in OUTLET VELOCITY 13.91 ft/s 0 CAGI 20 ft/s UPPER 30 ft/s
Header pressure profile
Pressure loss
0.4667 psi
Outlet gauge pressure
99.533 psig
Actual outlet velocity
13.913 ft/s4.2406 m/s
Loss of inlet gauge pressure
0.4667 %
Actual inlet velocity
13.856 ft/s
Effective inside diameter
1.61 in
Internal roughness used
1.7717 mil
Reynolds number
88,902
Darcy friction factor
0.022934
Outlet Mach number
0.012331

Formula and assumptions

Convert free air to mass flow

ṁ = ρstd Qstd · G = ṁ/A · v = GRT/Pabs

SCFM and Nm³/min describe free air. Actual line velocity uses the local absolute pressure and entered air temperature. For presets, the model uses the displayed inside diameter and roughness. Confirm aluminum system IDs and fitting data with the manufacturer.

Calculate line pressure loss

Pout² = Pin² − f (L + Leq) G²RT/D

This integrates Darcy–Weisbach friction at constant temperature using absolute pressure, fixed diameter, and a Churchill Darcy factor. Fitting equivalent lengths use the same pipe diameter. The model neglects elevation and gas acceleration. Confirm cases where outlet Mach exceeds 0.25.

Screen the velocity and pressure budget

Pressure loss (%) = 100 × (Pin − Pout)/Pin,gauge

CAGI’s pressure-drop brief recommends 20 ft/s or lower. The diagram marks 20–30 ft/s as a screening band, with 30 ft/s as the upper mark. The 5% pressure-loss notice is a separate planning check.

Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.

Worked examples