Horizontal Sheet Lift

Check normal pull-off on a flat sheet with four 80 mm-class effective cups.

Inputs

View results ↓
Cups and vacuum
in
inHg
Load and evacuation
lb
g
in³
ACFM

Results

Edit inputs ↑
Cup, workpiece, and holding forces NORMAL FORCE 275.6 lbfWORK LOAD 119.8 lbSAFETY FACT. 5.446 EVAC. TIME 0.5681 s CIRCULAR SEAL HOLD FORCE PAYLOAD 18 inHg HOLDING SAFETY FACTOR 5.446× / 2× 0× 2× REQUIRED 3×
Cup, workpiece, and holding forces
Theoretical normal holding force
275.59 lbf
Screened working load
119.82 lb
Calculated safety factor
5.4464
Ideal evacuation time
0.56805 s
Force available in load direction
275.59 lbf
Load before the safety factor
239.64 lb
Force required by payload
50.6 lbf
Minimum screening safety factor
2
Effective seal area per cup
7.7931 in²
Vacuum below atmosphere
18 inHg
Fraction of atmospheric vacuum
60.158 %
Target absolute pressure
5.8552 psia

Formula and assumptions

Calculate normal force

Fnormal = ΔP × n × πab/4

Use effective seal diameters a and b, not the outside dimensions of the cup. Equal axes describe a circular cup. A vacuum reading is the positive difference below ambient. Percent vacuum is relative to 101.325 kPa ambient.

Check load and orientation

Favailable = Fnormal (horizontal) or μFnormal (vertical) · Sactual = Favailable/[m(g + a)]

Horizontal workpieces are lifted normal to the surface. Vertical workpieces are held in shear. The screening minimums are 2 and 4 respectively. Use measured friction on the actual surface and account for uneven load sharing, moments, leakage, and loss of supply. Do not use this estimate to authorize a lift.

Estimate evacuation time

t = (V/Q) × ln(Pambient/Ptarget,abs)

Q is an effective actual volumetric suction rate at the evacuated system rather than an ejector’s compressed-air supply consumption. This isothermal estimate assumes constant suction speed and zero leakage. Confirm timing using the OEM evacuation curve, including valves, hoses, and dead volume.

Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.

Worked examples