Vertical Panel Shear Check

Check a wall-facing panel where a measured friction coefficient carries the weight.

Inputs

View results ↓
Cups and vacuum
in
inHg
Load and evacuation
lb
g
in³
ACFM

Results

Edit inputs ↑
Cup, workpiece, and holding forces NORMAL FORCE 571.6 lbfWORK LOAD 52.19 lbSAFETY FACT. 2.088 EVAC. TIME 0.6603 s CIRCULAR SEAL NORMAL FORCE SHEAR PAYLOAD 21 inHg HOLDING SAFETY FACTOR 2.088× / 4× 0× 4× REQUIRED 6×
Cup, workpiece, and holding forces
  • The calculated holding force falls below the selected orientation’s safety factor.
Theoretical normal holding force
571.59 lbf
Screened working load
52.189 lb
Calculated safety factor
2.0876
Ideal evacuation time
0.66029 s
Force available in load direction
240.07 lbf
Load before the safety factor
208.76 lb
Force required by payload
115 lbf
Minimum screening safety factor
4
Effective seal area per cup
13.854 in²
Vacuum below atmosphere
21 inHg
Fraction of atmospheric vacuum
70.184 %
Target absolute pressure
4.3817 psia

Formula and assumptions

Calculate normal force

Fnormal = ΔP × n × πab/4

Use effective seal diameters a and b, not the outside dimensions of the cup. Equal axes describe a circular cup. A vacuum reading is the positive difference below ambient. Percent vacuum is relative to 101.325 kPa ambient.

Check load and orientation

Favailable = Fnormal (horizontal) or μFnormal (vertical) · Sactual = Favailable/[m(g + a)]

Horizontal workpieces are lifted normal to the surface. Vertical workpieces are held in shear. The screening minimums are 2 and 4 respectively. Use measured friction on the actual surface and account for uneven load sharing, moments, leakage, and loss of supply. Do not use this estimate to authorize a lift.

Estimate evacuation time

t = (V/Q) × ln(Pambient/Ptarget,abs)

Q is an effective actual volumetric suction rate at the evacuated system rather than an ejector’s compressed-air supply consumption. This isothermal estimate assumes constant suction speed and zero leakage. Confirm timing using the OEM evacuation curve, including valves, hoses, and dead volume.

Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.

Worked examples