Evacuation Through a Long Hose
Compare evacuation of a larger hose and manifold volume at a fixed effective suction rate.
Inputs
View results ↓Results
Edit inputs ↑- Theoretical normal holding force
- 557.03 lbf
- Screened working load
- 253.19 lb
- Calculated safety factor
- 6.7518
- Ideal evacuation time
- 2.9546 s
- Force available in load direction
- 557.03 lbf
- Load before the safety factor
- 506.39 lb
- Force required by payload
- 82.5 lbf
- Minimum screening safety factor
- 2
- Effective seal area per cup
- 11.341 in²
- Vacuum below atmosphere
- 20 inHg
- Fraction of atmospheric vacuum
- 66.842 %
- Target absolute pressure
- 4.8729 psia
Formula and assumptions
Calculate normal force
Fnormal = ΔP × n × πab/4
Use effective seal diameters a and b, not the outside dimensions of the cup. Equal axes describe a circular cup. A vacuum reading is the positive difference below ambient. Percent vacuum is relative to 101.325 kPa ambient.
Check load and orientation
Favailable = Fnormal (horizontal) or μFnormal (vertical) · Sactual = Favailable/[m(g + a)]
Horizontal workpieces are lifted normal to the surface. Vertical workpieces are held in shear. The screening minimums are 2 and 4 respectively. Use measured friction on the actual surface and account for uneven load sharing, moments, leakage, and loss of supply. Do not use this estimate to authorize a lift.
Estimate evacuation time
t = (V/Q) × ln(Pambient/Ptarget,abs)
Q is an effective actual volumetric suction rate at the evacuated system rather than an ejector’s compressed-air supply consumption. This isothermal estimate assumes constant suction speed and zero leakage. Confirm timing using the OEM evacuation curve, including valves, hoses, and dead volume.
Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.
Worked examples
-
Horizontal Sheet Lift
Check normal pull-off on a flat sheet with four 80 mm-class effective cups.
-
Vertical Panel Shear Check
Check a wall-facing panel where a measured friction coefficient carries the weight.
-
Oval Cups on a Narrow Rail
Use oval cups to grip a long rail with a narrow sealing surface.
-
Ejector at 70% Vacuum
Check a small pick head when the ejector target is given as a percentage of atmospheric pressure.
-
Evacuation Through a Long Hose
Compare evacuation of a larger hose and manifold volume at a fixed effective suction rate.
-
Fast Pick With Added Acceleration
Check how a fast vertical acceleration changes the load margin on a horizontal sheet.