Oval Cups on a Narrow Rail

Use oval cups to grip a long rail with a narrow sealing surface.

Inputs

View results ↓
Cups and vacuum
mm
mm
kPa
Load and evacuation
kg
g
L
L/min

Results

Edit inputs ↑
Cup, workpiece, and holding forces NORMAL FORCE 1,252 NWORK LOAD 51.06 kgSAFETY FACT. 4.44 EVAC. TIME 0.5283 s OVAL SEAL HOLD FORCE PAYLOAD 55 kPa HOLDING SAFETY FACTOR 4.44× / 2× 0× 2× REQUIRED 3×
Cup, workpiece, and holding forces
Theoretical normal holding force
1,251.8 N
Screened working load
51.061 kg
Calculated safety factor
4.4401
Ideal evacuation time
0.52829 s
Force available in load direction
1,251.8 N
Load before the safety factor
102.12 kg
Force required by payload
281.94 N
Minimum screening safety factor
2
Effective seal area per cup
3,793.5 mm²
Vacuum below atmosphere
55 kPa
Fraction of atmospheric vacuum
54.281 %
Target absolute pressure
0.46325 bar(a)

Formula and assumptions

Calculate normal force

Fnormal = ΔP × n × πab/4

Use effective seal diameters a and b, not the outside dimensions of the cup. Equal axes describe a circular cup. A vacuum reading is the positive difference below ambient. Percent vacuum is relative to 101.325 kPa ambient.

Check load and orientation

Favailable = Fnormal (horizontal) or μFnormal (vertical) · Sactual = Favailable/[m(g + a)]

Horizontal workpieces are lifted normal to the surface. Vertical workpieces are held in shear. The screening minimums are 2 and 4 respectively. Use measured friction on the actual surface and account for uneven load sharing, moments, leakage, and loss of supply. Do not use this estimate to authorize a lift.

Estimate evacuation time

t = (V/Q) × ln(Pambient/Ptarget,abs)

Q is an effective actual volumetric suction rate at the evacuated system rather than an ejector’s compressed-air supply consumption. This isothermal estimate assumes constant suction speed and zero leakage. Confirm timing using the OEM evacuation curve, including valves, hoses, and dead volume.

Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.

Worked examples