Worked example
Dry Stabilizer for 12,000 Gallons, 20 to 40 ppm CYA
The target increase is 20 mg/L as cyanuric acid. Product purity determines how much dry stabilizer to weigh. Check the dissolved result before adding more.
Example readings
Results
Estimate- Dry stabilizer alternative
- 32.37 oz wt
- Liquid conditioner alternative
- 96 fl oz
- Calcium chloride estimate
- 0 oz wt
- Hardness increase
- 0 ppm
- Water replacement
- 0 %
- Water to replace
- 0 US gal
Export & share
Worked calculation
- 45,425 L × 20 mg/L ÷ 1,000 mg/g = 908.5 g of active CYA. Divide by the dry purity or liquid yield to convert it to product.
- Current CYA is at or below the target, so the dilution requirement is 0%.
- For calcium, 45,425 L × 0 mg/L as CaCO₃ ÷ 1,000 mg/g × (110.98 ÷ 100.0869) ÷ 77% purity = 0 g of calcium chloride product.
- Confirm CYA with a pool test kit before adding stabilizer. Liquid products vary by labeled yield. Allow the label’s mixing or dissolution time and retest before repeat dosing.
- A drain estimate is a concentration calculation. Ask a pool professional about groundwater, shell and liner limits and follow local discharge rules before removing water. Retest CYA, pH and calcium after refill.
- The hardness estimate assumes the entered calcium reading stays fixed. After a refill, use the new test reading for calcium dosing. Follow label handling precautions because calcium chloride can release heat in water.
Common questions
Why wait for this dry stabilizer to dissolve before re-dosing?
A prompt sample can miss undissolved product. Follow the label’s mixing and testing timeline to avoid exceeding the intended CYA.
Does a one-percentage-point purity difference change the dry dose?
Yes. Divide the required active CYA mass by 0.99 for 99% product. A fully active product would need the active mass itself.