Worked example

Dry Stabilizer for 12,000 Gallons, 20 to 40 ppm CYA

The target increase is 20 mg/L as cyanuric acid. Product purity determines how much dry stabilizer to weigh. Check the dissolved result before adding more.

Jump to results

Example readings

Cyanuric acid
US gal
ppm
ppm
ppm
%
g/L
1 US gal per 10,000 gal for +32 ppm equals 320 g/L.
Calcium hardness
ppm
ppm

Results

Estimate

Dry stabilizer alternative
32.37 oz wt
Liquid conditioner alternative
96 fl oz
Calcium chloride estimate
0 oz wt
Hardness increase
0 ppm
Water replacement
0 %
Water to replace
0 US gal
Stabilizer and hardness comparison
Cyanuric acid20 → 40 ppm0110Calcium hardness250 → 250 ppm0300

Export & share

Worked calculation

  1. 45,425 L × 20 mg/L ÷ 1,000 mg/g = 908.5 g of active CYA. Divide by the dry purity or liquid yield to convert it to product.
  2. Current CYA is at or below the target, so the dilution requirement is 0%.
  3. For calcium, 45,425 L × 0 mg/L as CaCO₃ ÷ 1,000 mg/g × (110.98 ÷ 100.0869) ÷ 77% purity = 0 g of calcium chloride product.
  • Confirm CYA with a pool test kit before adding stabilizer. Liquid products vary by labeled yield. Allow the label’s mixing or dissolution time and retest before repeat dosing.
  • A drain estimate is a concentration calculation. Ask a pool professional about groundwater, shell and liner limits and follow local discharge rules before removing water. Retest CYA, pH and calcium after refill.
  • The hardness estimate assumes the entered calcium reading stays fixed. After a refill, use the new test reading for calcium dosing. Follow label handling precautions because calcium chloride can release heat in water.

Common questions

Why wait for this dry stabilizer to dissolve before re-dosing?

A prompt sample can miss undissolved product. Follow the label’s mixing and testing timeline to avoid exceeding the intended CYA.

Does a one-percentage-point purity difference change the dry dose?

Yes. Divide the required active CYA mass by 0.99 for 99% product. A fully active product would need the active mass itself.

Method and safety references