Worked example
Lower CYA From 90 to 50 ppm When Fill Water Contains 10 ppm
The refill contributes some stabilizer of its own, so the concentration approaches the fill water’s reading. Enter that reading instead of assuming the source is zero.
Example readings
Results
Estimate- Water replacement
- 50 %
- Water to replace
- 9,000 US gal
- Dry stabilizer alternative
- 0 oz wt
- Liquid conditioner alternative
- 0 fl oz
- Calcium chloride estimate
- 0 oz wt
- Hardness increase
- 0 ppm
Export & share
Worked calculation
- 68,137 L × 0 mg/L ÷ 1,000 mg/g = 0 g of active CYA. Divide by the dry purity or liquid yield to convert it to product.
- (90 − 50) ÷ (90 − 10) = 50% replacement, or 9,000 US gal.
- For calcium, 68,137 L × 0 mg/L as CaCO₃ ÷ 1,000 mg/g × (110.98 ÷ 100.0869) ÷ 77% purity = 0 g of calcium chloride product.
- Confirm CYA with a pool test kit before adding stabilizer. Liquid products vary by labeled yield. Allow the label’s mixing or dissolution time and retest before repeat dosing.
- A drain estimate is a concentration calculation. Ask a pool professional about groundwater, shell and liner limits and follow local discharge rules before removing water. Retest CYA, pH and calcium after refill.
- The hardness estimate assumes the entered calcium reading stays fixed. After a refill, use the new test reading for calcium dosing. Follow label handling precautions because calcium chloride can release heat in water.
Common questions
Why divide the desired drop by 80 ppm in this refill example?
The pool is 80 ppm above the source water. That is the effective concentration difference per unit of water swapped.
What if fill water itself exceeds 50 ppm CYA?
The concentration after a swap lies between the start and the fill water. A source above the goal cannot reach the goal by dilution alone.