Worked example
90% Trichlor Equivalent for an 18,000-Gallon Pool
This is a chemical mass comparison for slow-feed trichlor. The amount corresponds to the FC change after release. Tablet feed rate and water demand determine what actually appears on the test.
Example readings
Results
Estimate- Dry product estimate
- 8.01 oz wt
- Free chlorine increase
- 3 ppm
- Ratio minimum FC
- 3.75 ppm
- Ratio target FC
- 5.75 ppm
- Shock comparison FC
- 20 ppm
- Selected FC goal
- 5 ppm
- Current FC / CYA
- 4 %
- Added CYA
- 1.83 ppm
- Added calcium hardness
- 0 ppm
Export & share
Worked calculation
- (5 ppm selected − 2 ppm current), with a floor of zero, gives a 3 ppm rise.
- 68,137 L × 3 mg/L ÷ 1,000 = 204.41 g chlorine equivalent.
- 204.41 g ÷ 90% available chlorine = 227.12 g dry product (8.01 oz wt).
- With 50 ppm CYA in 18,000 US gal, the starting FC/CYA ratio is 4%.
- The ratio bands are residential outdoor planning benchmarks. Treatment limits, sanitizer labels and local rules govern actual additions. Keep swimmers out during elevated-chlorine treatment and retest before reopening.
- Liquid strengths use label weight percent sodium hypochlorite and a typical product density. Use plain pool-labeled chlorine. Verify the product concentration and free chlorine with a DPD or FAS-DPD test.
- The chlorine source also raises CYA. This estimate uses starting CYA, so recalculate with the new CYA before planning repeat doses. Follow feeder directions for trichlor tablets.
Common questions
Can the trichlor mass be poured into a cal-hypo feeder?
Never place trichlor in a feeder used for another chlorine type. Use only equipment and placement approved by the trichlor label.
Why does trichlor release timing matter for interpreting this dose?
The tablets dissolve over time, so chlorine demand can consume some output as it is released. Use the pool test history to adjust the feeder.