ENGINEERING BASIS

Calculation methodology

Preliminary screening only. Verify the governing code edition and obtain stamped engineering approval before fabrication, testing, or service.

Read the screening verdict

Each margin compares two quantities for the stated model. A pass means the entered case satisfies that comparison. Confirm the adopted code edition, material allowable stresses, design loads, actual geometry and certified components through your engineering approval process.

Inputs and results can be displayed in U.S. customary or metric SI. The models preserve the customary calculation basis and convert the display. Gauge pressure references local atmosphere. Absolute pressure is used in gas expansion and valve flow, and external pressure is a differential.

Worked examples are illustrative. Their original presets appear beside the live calculation basis and can be edited or restored. Calculations use unrounded values and the readout rounds for display.

ASME VIII-1 / UG-27

Shell thickness & MAWP

Use local gauge design pressure, including static head where applicable. This screen covers pressure-only wall in the stated UG-27 range. Confirm UG-16 minimums, allowable stresses, weld examination, external loads, and each pressure-boundary part.

ASME VIII-1 / UG-37 & UG-40

Nozzle reinforcement

Screen one isolated radial set-in opening in a pressurized cylindrical wall. Verify UG-36 limits, the governing reinforcement planes, weld load paths, UG-45 neck thickness, nearby openings, external loads and attachment details.

ASME VIII-1 / UG-99 & UG-100

Proof test pressure

Pneumatic failure can release severe stored energy. Obtain an approved test procedure and pressure-safety review. Hydrostatic weight and actual vessel support, venting, metal temperature, component limits and allowable stress at test conditions require review.

ASME B16.5 / APPENDIX 2

Flange rating & bolt torque

Rating data cover 150, 300, 400, 600, 900 and 1500 for the shown grades. The customary range starts at −20°F and ends at 1,000°F for SA-105, F304 and F316, 800°F for F304L and 850°F for F316L. Confirm the intended edition, product form, flange geometry, gasket limits, stress at temperature, and PCC-1 assembly procedure.

ASME VIII-1 / UG-28 SCREEN

Vacuum collapse & spacing

Comparative thin-shell screening for D/t ≥ 20 and L/D ≥ 0.2. UG-28 allowable pressure requires the project material A/B chart and correct unsupported length. Verify ovality, fabrication tolerances, heads, combined loads and ring inertia or attachment under UG-29/UG-30.

VESSEL GEOMETRY / STATIC LOADS

Vessel volume & saddle loads

Strapping data cover ideal horizontal geometry at the entered dimensions, with zero volume at zero depth. Confirm surveyed tank geometry and calibration for inventory use. Saddle reactions exclude local stresses, anchors, flexure, and seismic or wind loads.

API 520 / API 526

Relief valve orifice sizing

Use an independently established relief load and actual relieving conditions. Verify API 520 method applicability, allowable backpressure and installation, flashing or two-phase flow, valve certification, and manufacturer-rated capacity.