ASME VIII-1 / UG-37 & UG-40
Nozzle opening reinforcement area calculator
Balance opening area against net shell, neck, weld and pad credit for an isolated radial set-in nozzle.
Inputs
Results update as inputs change. View results ↑
Screening result
Edit inputs ↓ LiveArea replacement covers one radial opening and one plane. Check all required planes, neck minimums, load paths and weld strength.
Calculation breakdown
- Base removed area d·tᵣ·F
- 2.1 in²
- Required area with strength correction
- 2.1 in²
- A₁ shell excess
- 0.9 in²
- A₂ outward nozzle excess
- 0.19 in²
- A₃ inward nozzle projection
- 0.14 in²
- A₄ fillet welds
- 0.0693 in²
- A₅ pad metal
- 0.985 in²
- Total credited area
- 2.2843 in²
- Net area balance
- 0.1843 in²
- Independent wall check
- Shell and neck meet inputs
- Nozzle outside diameter
- 6.56 in
- Creditable pad diameter limit
- 12 in
- Candidate OD at entered pad wall
- 10.1824 in
- Candidate wall at entered pad OD
- 0.2298 in
- Credited pad wall
- 0.25 in
- Pad sizing screen
- Candidate within zone
Calculation basis
Required area
Increase the removed pressure-wall area when the nozzle material is weaker than the shell. Use F = 1.00 for padded and non-integrally reinforced openings. Enter a lower F only for a verified integrally reinforced opening and plane. Use dimensions after corrosion.
A = d·tᵣ·F + 2tₙ·tᵣ·F(1 − fᵣ)Eligible credit
Keep neck and equal-leg fillet credit within the radial and normal limits. The outward fillet uses the weaker of neck and pad when it joins a pad. The inward projection assumes the entered net neck wall also applies inside.
Aavailable = A₁ + A₂ + A₃ + A₄ + A₅Pad sizing
Credit pad width between nozzle OD and the radial boundary. Candidate pad sizes use pad-free outward neck height and omit outer fillet credit to keep the geometry change conservative. A dash indicates that a candidate is inapplicable or exceeds the modeled zone.
A₅ = (ODcredited − ODneck)·tpad·fpad
Screen one isolated radial set-in opening in a pressurized cylindrical wall. Verify UG-36 limits, the governing reinforcement planes, weld load paths, UG-45 neck thickness, nearby openings, external loads and attachment details.