API 520 / API 526
Viscous incompressible liquid relief
A nonflashing liquid at 420 US gpm uses an entered specific gravity of 0.88 and viscosity factor of 0.72.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LiveAPI letter is based on effective area. Confirm certified capacity, backpressure limits, inlet losses and the relieving scenario before selection.
Calculation breakdown
- Required effective area
- 1.8362 in²
- API 526 letter
- K
- Selected API effective area
- 1.838 in²
- Area reserve vs selected or largest letter
- 0.0018 in²
- Required percent of reference area
- 99.9 %
- Required equivalent circular bore
- 1.529 in
- Inlet to outlet differential
- 195 psid
- Absolute outlet / inlet ratio
- 18.75 %
- Gas critical ratio
- —
- US gas coefficient C
- —
- Napier high-pressure factor Kn
- —
- Effective reference mass flow
- —
- Effective reference liquid flow
- 420.402 US gpm
Worked calculation
A nonflashing liquid at 420 US gpm uses an entered specific gravity of 0.88 and viscosity factor of 0.72.
- Required effective area
- 1.8362 in²
- Inlet to outlet differential
- 195 psid
- Effective reference liquid flow
- 420.402 US gpm
Use inlet minus outlet pressure as the driving differential. The lower viscosity factor increases the required effective area.
Calculation basis
Gas at critical flow
Check the absolute outlet-to-inlet ratio against the critical ratio. Use relieving temperature in Rankine in the customary equation. P₁ represents the actual valve inlet under relief, including the applicable overpressure and inlet losses.
W = C·Kd·P₁·Kb·Kc·A·√(M/(T·Z)) · C = 520√[k(2/(k+1))^((k+1)/(k−1))]Steam and liquid
Use Ksh = 1 for saturated steam. The Napier correction Kn applies above 1,500 psia through 3,200 psia. This screen assumes low outlet pressure for steam. The liquid equation uses US gal/min and verified correction factors.
Wsteam = 51.5·P₁·A·Kd·Kb·Kc·Kn·Ksh · Qliquid = 38·Kd·Kw·Kc·Kv·A·√(ΔP/G)API effective letter
Choose the smallest D through T area meeting the computed requirement. If the demand exceeds T, compare against T as a reference and flag the case for engineering review.
Utilization = 100 × Arequired / Areference
Use an independently established relief load and actual relieving conditions. Verify API 520 method applicability, allowable backpressure and installation, flashing or two-phase flow, valve certification, and manufacturer-rated capacity.