API 520 / API 526

Viscous incompressible liquid relief

A nonflashing liquid at 420 US gpm uses an entered specific gravity of 0.88 and viscosity factor of 0.72.

Inputs

Relieving fluid and pressure
psia
psia
US gpm
Effective sizing factors

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
REQUIRED AREA 1.836 in² API LETTER K SELECTED AREA 1.838 in² UTILIZATION 99.9 % ORIFICE & VALVE Effective areaValve sectionLIQUID Orifice area headroom PASS SCREEN 0% 100% LIMIT 150%+
1.8362 in² demand / 1.838 in² limit

API letter is based on effective area. Confirm certified capacity, backpressure limits, inlet losses and the relieving scenario before selection.

Export or share
Calculation breakdown
Required effective area
1.8362 in²
API 526 letter
K
Selected API effective area
1.838 in²
Area reserve vs selected or largest letter
0.0018 in²
Required percent of reference area
99.9 %
Required equivalent circular bore
1.529 in
Inlet to outlet differential
195 psid
Absolute outlet / inlet ratio
18.75 %
Gas critical ratio
—
US gas coefficient C
—
Napier high-pressure factor Kn
—
Effective reference mass flow
—
Effective reference liquid flow
420.402 US gpm
ORIGINAL PRESET

Worked calculation

A nonflashing liquid at 420 US gpm uses an entered specific gravity of 0.88 and viscosity factor of 0.72.

Required effective area
1.8362 in²
Inlet to outlet differential
195 psid
Effective reference liquid flow
420.402 US gpm

Use inlet minus outlet pressure as the driving differential. The lower viscosity factor increases the required effective area.

Calculation basis

  1. Gas at critical flow

    Check the absolute outlet-to-inlet ratio against the critical ratio. Use relieving temperature in Rankine in the customary equation. P₁ represents the actual valve inlet under relief, including the applicable overpressure and inlet losses.

    W = C·Kd·P₁·Kb·Kc·A·√(M/(T·Z)) · C = 520√[k(2/(k+1))^((k+1)/(k−1))]

  2. Steam and liquid

    Use Ksh = 1 for saturated steam. The Napier correction Kn applies above 1,500 psia through 3,200 psia. This screen assumes low outlet pressure for steam. The liquid equation uses US gal/min and verified correction factors.

    Wsteam = 51.5·P₁·A·Kd·Kb·Kc·Kn·Ksh · Qliquid = 38·Kd·Kw·Kc·Kv·A·√(ΔP/G)

  3. API effective letter

    Choose the smallest D through T area meeting the computed requirement. If the demand exceeds T, compare against T as a reference and flag the case for engineering review.

    Utilization = 100 × Arequired / Areference

Use an independently established relief load and actual relieving conditions. Verify API 520 method applicability, allowable backpressure and installation, flashing or two-phase flow, valve certification, and manufacturer-rated capacity.

Sources and verification scope ↗