IEC 60534-8-3 screening context

Outlet exceeds the Mach model limit

A small gas outlet is tested against a mass-flow requirement at very low downstream absolute pressure.

Inputs

Gas duty
Outlet and noise basis
Fraction of proxy flow power converted to acoustic power. Use an OEM estimate when available.
Noise at 1 m
88dBA
Exit Mach
4.261
Exit velocity
1,157.1m/s
85 dBA margin
-3dB
Exit flow model limit

The algebraic exit Mach is at least 1. A compressible-flow and acoustic assessment is required.

Exit Mach and acoustic margin

Exit Mach and acoustic marginThe 85 dBA mark is an exposure-screening reference. Use a measured 8-hour time-weighted average for OSHA assessment.LEVEL AT 1 M88 dBAEXIT MACH4.26185 dBA45 dBA125 dBAA-WEIGHTED SCREENESTIMATE88 dBAACTION REF.85 dBA85 dBA MARGIN-3 dB
The 85 dBA mark is an exposure-screening reference. Use a measured 8-hour time-weighted average for OSHA assessment.

All calculated values
External sound level at 1 m88 dBA
Margin to 85 dBA reference-3 dB
Outlet-pipe Mach number4.261
Trim velocity screenReview low-noise trim
Outlet velocity1,157.12 m/s
Local speed of sound271.56 m/s
Ideal-gas outlet density1.364 kg/m³
Absolute pressure ratio P₂ / P₁0.0975
Outlet pipe ID38.1 mm
Outlet wall thickness5.08 mm
Estimated transmission loss34.8 dB
Available flow-power proxy239,539.01 W
Estimated source acoustic power23.954 W

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Calculate outlet Mach4.261
  2. Estimate external noise at 1 m88 dBA
  3. Compare with the 85 dBA reference-3 dB

The ideal-gas outlet calculation crosses Mach 1. The screening values flag the case for a compressible-flow model.

Model and limits

The gas-only estimate uses dry, single-phase ideal-gas density at outlet pressure and temperature, nominal outlet ID and a user-entered acoustic efficiency. The 1 m sound level is a free-field power proxy with a user-entered A-weighting offset.

The full IEC model requires OEM data and frequency-dependent transmission. The schedule correction here is a relative mass-law estimate. Mach above 0.30 prompts an exit velocity and low-noise trim review. Mach of 1 or higher indicates the simplified outlet model has exceeded its useful range. The 85 dBA OSHA hearing conservation action level is an 8-hour TWA. The margin to a 1 m estimate is a screening comparison.

View equations and references

Worked examples