IEC 60534-8-3 screening context
Schedule 160 gas outlet attenuation
A gas control station compares heavier outlet wall with its Schedule 40 reference loss.
Inputs
Results
Edit inputs- Noise at 1 m
- 80.2dBA
- Exit Mach
- 0.063
- Exit velocity
- 71.6ft/s
- 85 dBA margin
- 4.8dB
The estimated 1 m level is below 85 dBA and exit Mach is within 0.30.
Exit Mach and acoustic margin
All calculated values
| External sound level at 1 m | 80.2 dBA |
|---|---|
| Margin to 85 dBA reference | 4.8 dB |
| Outlet-pipe Mach number | 0.0626 |
| Trim velocity screen | Standard screen |
| Outlet velocity | 71.58 ft/s |
| Local speed of sound | 1,144.09 ft/s |
| Ideal-gas outlet density | 0.357 lb/ft³ |
| Absolute pressure ratio P₂ / P₁ | 0.5538 |
| Outlet pipe ID | 5.187 in |
| Outlet wall thickness | 0.719 in |
| Estimated transmission loss | 38.2 dB |
| Available flow-power proxy | 87,248.53 W |
| Estimated source acoustic power | 8.725 W |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Calculate outlet Mach0.0626
- Estimate external noise at 1 m80.2 dBA
- Compare with the 85 dBA reference4.8 dB
Additional wall can improve this simple attenuation estimate while reducing inside diameter. Check both acoustic margin and exit Mach.
Model and limits
The gas-only estimate uses dry, single-phase ideal-gas density at outlet pressure and temperature, nominal outlet ID and a user-entered acoustic efficiency. The 1 m sound level is a free-field power proxy with a user-entered A-weighting offset.
The full IEC model requires OEM data and frequency-dependent transmission. The schedule correction here is a relative mass-law estimate. Mach above 0.30 prompts an exit velocity and low-noise trim review. Mach of 1 or higher indicates the simplified outlet model has exceeded its useful range. The 85 dBA OSHA hearing conservation action level is an 8-hour TWA. The margin to a 1 m estimate is a screening comparison.
View equations and references