Engineering basis

Methodology

Engineering screening estimates. Verify the duty with OEM sizing software and have a qualified professional engineer review the design before selection or installation.

IEC 60534-2-1 / ISA-75.01

Liquid valve sizing

Use absolute inlet, outlet, vapor and critical pressures for the single-phase turbulent liquid sizing basis. Specific gravity is relative to water. Use vapor pressure at the actual flowing temperature.

  • Fꜰ = 0.96 − 0.28 √(Pᵥ / P꜀)
  • ΔPchoke = Fₗ² (P₁ − Fꜰ Pᵥ) for a bare valve, or (Fₗₚ / Fₚ)² (P₁ − Fꜰ Pᵥ) with fittings
  • ΔPsize = min(P₁ − P₂, ΔPchoke)
  • Cv = Q[GPM] √(SG / ΔPsize[psi]) / Fₚ
  • Kv ≈ 0.865 Cv
  • σ = (P₁ − Pᵥ) / (P₁ − P₂)

Enter matching OEM Fₗₚ and Fₚ for attached fittings. A zero Fₗₚ leaves a bare-valve choke estimate. The pressure profile divides the effective drop by the square of the recovery factor to estimate throat pressure. A low σ or throat pressure indicates cavitation risk. P₂ below Pᵥ indicates flashing. Trim-specific σᵢ, viscous correction, damage limits and multiphase flow require separate review.

References

Open calculator

Installed flow characteristic

Valve authority

Full-open valve authority is the fraction of the available differential consumed by the fully open valve. The installed curve assumes fixed available differential and square-law friction outside the valve.

  • a = ΔPᵥ / (ΔPᵥ + ΔPsys)
  • fᵢ = h (linear), R^(h − 1) (equal percentage), √h (quick opening)
  • f = fᵢ / √[a + (1 − a) fᵢ²]

Travel h and flow fractions run from 0 to 1. At shutoff all trims are set to zero. Equal-percentage rangeability applies over the throttling range just above shutoff. Quick opening uses an illustrative square-root curve. Authority below 0.25 prompts a loop review. Use actual OEM Cv versus travel and system characteristics for control tuning.

References

Open calculator

ISO 5167-2 / ASME MFC-3M

Orifice flowmeter

The screen uses a concentric sharp-edged plate in a full pipe, inlet density, an entered discharge coefficient and expansibility. The default Cd of 0.61 is a screening estimate. Enter a calibrated value or calculate Cd for your tapping geometry. For a liquid, set expansibility to 1. The velocity-of-approach factor is included in E.

  • β = d / D and E = ε / √(1 − β⁴)
  • Q = Cd E (π d² / 4) √(2 ΔP / ρ)
  • Re = 4 ρ Q / (π μ D)
  • ΔPperm ≈ (1 − β^1.9) ΔP
  • Cost = Q ΔPperm × annual hours × tariff / (1000 η)

The screen uses β from 0.20 to 0.75, pipe ID from 50 to 1,000 mm and bore of at least 12.5 mm. It uses the largest Reynolds floor for corner, D and D/2, and flange tappings. Confirm the actual tapping limits, straight runs, roughness, Cd and gas expansibility. The permanent-loss multiplier is an approximation. Gas volume is at inlet conditions and the energy estimate is a hydraulic power proxy.

References

Open calculator

Joukowsky / elastic pipe

Water hammer

The elastic wall model represents one full liquid line between the valve and a reflecting boundary. Enter the effective closure time and the velocity reduction across the event. Use a consistent gauge pressure basis for initial pressure and rating.

  • a = √[(K / ρ) / (1 + KD / Ee)]
  • T꜀ = 2 L / a
  • ΔP = ρ a Δv × min(1, T꜀ / t꜀)
  • Ppeak = Pinitial + ΔP

Instantaneous closure uses the full Joukowsky rise. The slow-closure factor is a linear-closure approximation. Preset pipe moduli are nominal short-term values. Check restraint, viscoelasticity, nonlinear closure, branches, reflected waves and vapor-column separation with transient analysis. Enter the temperature-corrected rating of the weakest relevant component.

References

Open calculator

ASME B31.3 flexibility screen

Thermal expansion loop

Use the length between effective anchors and the install-to-operating temperature difference. The guided-cantilever screen assigns the full displacement to a single L-leg or shares it equally across the two idealized legs of a Z-offset or U-loop.

  • ΔL = α L (Toperating − Tinstall)
  • Δleg = |ΔL| / n with n = 1 or 2
  • Lmin = √(3 E Dₒ Δleg / Sₐ)
  • Sscreen = 3 E Dₒ Δleg / Lprovided²
  • U-loop W = H × entered width-to-height ratio

Use a project-approved allowable displacement stress range Sₐ. Representative moduli and coefficients are constant over the entered temperature range. Confirm temperature-dependent properties, anchor loads, direction of movement, elbow flexibility, fatigue cycles and stress intensification using the governing B31.3 edition and a pipe stress analysis. U-loop width is a layout estimate from the entered aspect ratio.

References

Open calculator

ASME B31.1 / B31.3 beam screen

Pipe support span

The steel section uses nominal OD and wall dimensions. The distributed load includes the steel wall, full contents when selected, and the insulated annulus. The choice is between a simply supported span and two equal continuous spans carrying the same uniform load.

  • I = π (Dₒ⁴ − Dᵢ⁴) / 64 and Z = 2 I / Dₒ
  • δmid = 5 w L⁴ / (384 EI) for a simple span
  • δmid = w L⁴ / (192 EI) for two equal spans
  • σmax = w L² / (8 Z) and Lmax = min(Lsag, Lstress)

Default peak sag allowance is 0.10 in (2.54 mm). The sag peak for two equal spans is at about 42% of span from the outer support. The largest absolute bending moment is at the interior support. Include pressure, localized component loads, thermal loads, corrosion, support stiffness and combined sustained stress in the final B31.1 or B31.3 review.

References

Open calculator

Pneumatic rack-and-pinion

Actuator torque

Enter OEM breakaway, running and seating torque at the reference differential. Demand uses a service multiplier and a provisional valve-type correction of the form b + (1 − b) ΔP/ΔPref. Base fractions b are 0.35 for floating ball, 0.55 for trunnion, 0.50 for butterfly and 0.65 for plug.

  • Trequired = TOEM × service multiplier × pressure correction
  • Tgross = 2 Pₐᵢᵣ (π bore² / 4) rpinion η
  • Tair = max(0, Tgross − opposing spring torque)
  • Margin = least of the output minus demand points

Set the reference differential to the service differential when using OEM torque data for that duty. The equivalent bore assumes two equal pistons and constant pitch radius. It sizes the air side only. Use vendor start, mid-stroke and end torque tables for both directions, minimum air available while stroking, stem limits at maximum supply, and the actual fail-safe spring set.

References

Open calculator

IEC 60534-8-3 screening context

Trim noise & exit Mach

The gas-only estimate uses dry, single-phase ideal-gas density at outlet pressure and temperature, nominal outlet ID and a user-entered acoustic efficiency. The 1 m sound level is a free-field power proxy with a user-entered A-weighting offset.

  • ρ₂ = P₂ / (R T₂) and v₂ = ṁ / (ρ₂ A₂)
  • M = v₂ / √(γ R T₂)
  • Wac = ηac ṁ R T₂ ln(P₁ / P₂)
  • TL = TL₄₀ + 20 log₁₀(t / t₄₀)
  • LpA(1 m) = 10 log₁₀(Wac / 10⁻¹² W) − 10 log₁₀(4π) − TL + Aoffset

The full IEC model requires OEM data and frequency-dependent transmission. The schedule correction here is a relative mass-law estimate. Mach above 0.30 prompts an exit velocity and low-noise trim review. Mach of 1 or higher indicates the simplified outlet model has exceeded its useful range. The 85 dBA OSHA hearing conservation action level is an 8-hour TWA. The margin to a 1 m estimate is a screening comparison.

References