Joukowsky / elastic pipe

Slow closure on a ductile-iron line

A ductile-iron distribution line uses a motorized valve with 3.5 seconds of effective closure time.

Inputs

Liquid and pipe
Closure and pressure
Wave speed
1,300.3m/s
Critical time
0.338s
Surge rise
213.3kPa
Peak pressure
6.4bar g
Peak within entered rating

Slow closure gives a peak at or below the rating. Transient reflections and vacuum require separate review.

Joukowsky surge envelope

Joukowsky surge envelopePeak pressure versus closure time on a compressed time scale. The dashed vertical line marks the round-trip time.01429bar g0 sCLOSURE TIME4 sPEAK ENVELOPEPIPE RATINGPEAK6.4 bar gRATING16 bar gMARGIN956.7 kPa
Peak pressure versus closure time on a compressed time scale. The dashed vertical line marks the round-trip time.

All calculated values
Elastic wave speed1,300.3 m/s
Round-trip time0.3384 s
Closure regimeSlow
Instantaneous Joukowsky rise2,206.16 kPa
Closure-adjusted surge rise213.29 kPa
Peak line pressure6.43 bar g
Remaining rating margin956.71 kPa
Rating used40.2 %
Nominal wall modulus E165 GPa
Diameter-to-wall ratio22.8

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Find the elastic wave speed1,300.3 m/s
  2. Compare closure with round-trip time0.3384 s
  3. Add surge to line pressure6.43 bar g

The screen attenuates the sudden pressure rise because closure exceeds a round trip. Actual closure depends on the valve characteristic.

Model and limits

The elastic wall model represents one full liquid line between the valve and a reflecting boundary. Enter the effective closure time and the velocity reduction across the event. Use a consistent gauge pressure basis for initial pressure and rating.

Instantaneous closure uses the full Joukowsky rise. The slow-closure factor is a linear-closure approximation. Preset pipe moduli are nominal short-term values. Check restraint, viscoelasticity, nonlinear closure, branches, reflected waves and vapor-column separation with transient analysis. Enter the temperature-corrected rating of the weakest relevant component.

View equations and references

Worked examples